24
Part Number: 9291458 REV00 12/19
Installation
Section 2
SELF-CONTAINED REFRIGERATED DROP-IN UNITS
8200P, N8200-GP, N8200-STP
For any non-standard installation consult the factory.
1. Install a GFCI receptacle a minimum of 14” (36cm) up
from the cabinet bottom inside the partitions. We
recommend installing a remote located power switch
for ease of use
2. Cabinet interior minimum dimensions:
Dimension
N8231P/GP
N8245P/GP
N8259P/GP
A
30.75"/78cm
44.25"/112cm
58.5"/149cm
B
27.75"/70cm
27.75"/70cm
27.75"/70cm
C
26"/66cm
26"/66cm
26"/66cm
D
30.75"/78cm
44.25"/112cm
58.5"/149cm
E
25"/64cm
25"/64cm
25"/64cm
F
Min. 2.75”/7cm - Max. 4.75”/12cm
Dimension
N8273P/GP
N8287P/GP
A
72.38"/184cm 86.25"/219cm
B
27.75"/70cm
27.75"/70cm
C
26"/66cm
26"/66cm
D
72.38"/184cm 86.25"/219cm
E
25"/64cm
25"/64cm
F
Min. 2.75”/7cm - Max. 4.75”/12cm
Dimension
N8230-STP
N8240-STP
N8256-STP
A
28.6"/73cm
38.65"/98cm
54.6"/139cm
B
27.75"/70cm
27.75"/70cm
27.75"/70cm
C
26"/66cm
26"/66cm
26"/66cm
D
30.75"/78cm
44.63"/113cm
58.5"/149cm
E
21.12"/54cm
28.75"/73cm
21.12"/54cm
F
Min. 2.75”/7cm - Max. 4.75”/12cm
Dimension
N8258-STP
N8275-STP
A
56.6"/144cm
74.5"/189cm
B
27.75"/70cm
27.75"/70cm
C
26"/66cm
26"/66cm
D
72.38"/184cm 86.25"/219cm
E
28.75"/73cm
28.75"/73cm
F
Min. 2.75”/7cm - Max. 4.75”/12cm
3. Place the condensing unit through the counter cutout.
4. Extend the telescoping duct from the front of the
condensing unit to the back of the louver. This will
prevent recirculation of discharge air. Export models do
not have a telescoping duct, skip to step 6.
22.50”
(57cm)
C
E
D
A
B
11.50”
(29cm)
F
5. Put eight provided screws through the telescoping
duct side walls to hold it at the desired depth.