2 // INSTALLING YOUR APPLIANCE
•
Your hob must be connected to a
220-240 V~ single phase mains supply via a
standard IEC 60083 2 pole + earth electrical
plug or an all-pole isolator, in compliance
with the current installation regulations.
The electrical plug must remain accessible
after installation.
— Connect the wires to the electricity supply,
taking note of the colour of each wire (see
diagram opposite).
When power is first supplied to your hob, or
after an extended power cut, an indicator
light will be displayed on the control panel.
This information will disappear after
20 seconds.
ELECTRICAL CONNECTION
C
ROSS-SECTION OF CABLE TO BE USED
—
The safety wire (green and yellow) is connected to the appliance’s earth
terminal
and must be connected to the mains earth terminal
.
—
If the power cable is damaged, it must be replaced by the manufacturer, the After-
Sales Service or a similarly qualified person, to avoid any risk.
Neutral
(N)
Phase
(L)
Earth
Green and
yellow wire
Blue wire
Black, brown
or red wire
Model
DTG1127*
Model
DTI1127*
220-240 V~ - 50 Hz
220-240 V~ - 50 Hz
H05V2V2F - T90
3 conductors
including
1 for earth
Cross-section of
conductors in mm²
1
1.5
Fuse
10A
16A