![DeDietrich DTI 1127 X Manual For Installation And Use Download Page 44](http://html1.mh-extra.com/html/dedietrich/dti-1127-x/dti-1127-x_manual-for-installation-and-use_2462655044.webp)
Installation should only be undertaken by
qualified fitters and technicians.
Before installation, ensure that the
conditions of local distribution (gas type
and pressure) and the settings of the
appliance are compatible.
The setting conditions for this hob are printed
on a sticker inside the instruction guide
pouch and on the packaging.
As it is not connected to a system for
removing combustion by-products, it must be
installed in compliance with current
regulations and used in a well-ventilated area.
Special attention should be given to
ventilation regulations.
In this regard, as combustion can only take
place in the presence of the oxygen in the air,
the latter must be continually renewed and
combustion by-products evacuated (a
minimum flow rate of 2 m3/h per kW of gas
power is required.
Example:
- Total power = 0.85 + 1.5 + 2.25 + 3.1 = 7.7 kW.
7.7 kW x 2 = 15.4 m3/h minimum air flow.
These tables comply with the heating of
cabinets in accordance with standard
EN 60335-2-6 and class 3 as regards the
installation (in accordance with standard
EN 30-1-1).
44
EN
2
2 // INSTALLING YOUR APPLIANCE
• TIPS FOR FLUSH MOUNTING
Depending on cabinet
Width
Depth
Thickness
Cabinet cut-out
Model
56 cm
49 cm
Overall dimensions
above the work top
65 cm
51.8 cm
5 cm
Overall dimensions
below the work top
55 cm
47 cm
5.1 cm