![DEC 3000 800 Owner'S Manual Download Page 224](http://html1.mh-extra.com/html/dec/3000-800/3000-800_owners-manual_2461324224.webp)
Running Diagnostic Tests
Example
TURBOchannel
Test
To test a device connected to slot 2, enter the following command:
>>> test tc2
Return
To show the configuration of a device connected to slot 2, enter
the following command:
>>> test tc2 cnfg
Return
If test_name contains a slash (/) or a hyphen (-), enclose test_
name in double quotes.
Initializing Your
System
After you have run a test, you should use the following command
to initialize your system to clear the error log from the system
register. Figure 14–3 shows an example of the
init
command.
Figure 14–3 Initializing Your System
>>> init
Return
INIT-S-CPU...
INIT-S-RESET_TC...
INIT-S-ASIC...
INIT-S-MEMO...
INIT-S-NVR...
INIT-S-SCC...
INIT-S-NI...
INIT-S-SCSI...
INIT-S-ISDN...
>>>
14–8 Running Diagnostic Tests