![DEC 3000 800 Owner'S Manual Download Page 104](http://html1.mh-extra.com/html/dec/3000-800/3000-800_owners-manual_2461324104.webp)
Setting and Verifying the Network Connection
Set the Network
Type
You set the network type from console mode. To set the network
type, complete the following steps:
1.
Start your system as Chapter 6 describes.
2.
If your system does not stop at the console prompt after
the startup tests, press the halt button on the front of
your system unit to display the console prompt (>>>). See
Figure 2–10 for the location of the halt button.
3.
Enter the following command and press the Return key:
>>> set ethernet
network_type
Return
ETHERNET =
network_type
The variable network_type is either THICK or TENBT,
depending on which network you are using.
Verify the
Network
Connection
Once you have set the network type, you can verify the network
connections by entering the
test ni
command at the console
prompt as follows. The
test ni
command tests the Ethernet
network interface (NI).
>>>test ni
Return
Successful
Result of
test ni
If the
test ni
test is successful, you will see a display similar to
the following:
>>> test ni
Return
T-STS-NI - OK
>>>
Error Detected
During test ni
If the network test detects an error, you will see a display similar
to the following:
>>> test ni
Return
T-ERR-NI - Ext Lpbk test failed
?? 000 NI 0x00f2
84 FAIL
>>>
5–12 Connecting the System to a Network
Summary of Contents for 3000 800
Page 14: ......
Page 20: ......
Page 34: ......
Page 54: ......
Page 92: ......
Page 106: ......
Page 130: ......
Page 138: ......
Page 140: ......
Page 186: ......
Page 193: ...Startup Problems Figure 13 1 Power Indicator Light 1 2 MLO 008922 Identifying a Problem 13 7...
Page 216: ......
Page 236: ......
Page 238: ......
Page 260: ......
Page 266: ......
Page 310: ......
Page 318: ......