2 PRODUCT DESCRIPTION
Models and contents of the package
The name STOP N identi
fi
es a series of electromechanical barriers with different characteristics with regard to the motor power supply,
the speed of movement and the maximum length of the boom. All motorized models foresee the use of advanced control units (NET series)
equipped with anti-crush sensor, built-in 433 MHz radio receiver, speed adjustment and slow down during opening and closing.
The STOP N barriers are designed for intensive use and high traf
fi
c areas.
The choice of the barrier must be made depending on the width of the access point and the required work cycle.
The
DEA
System complementary accessories are indicated in the table “PRODUCT ACCESSORIES” (pag. I-8).
The STOP N barriers have a built-in electro-mechanical operator which is connected directly to the shaft which raises and lowers the
boom, while the boom balancing by setting up the springs to the appropriate tension.
The automation control is enclosed in a steel box in painted steel (or stainless steel) with a lockable door. The control panel is installed
inside the door cover for full access.
Transport
STOP N is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all information
that may be provided on the same box for storage and handling.
3 TECHNICAL DATA
CONTROL BOARD
NET24N
Power supply (V)
230 V ~ ±10% (50/60 Hz)
Rated power transformer (VA)
4÷5 m
≥
6 m
150 VA
(230/22V)
250 VA*
(230/22V)
Fuse F2 (A) (transformer)
2A
3,15A*
Batteries
2x 12V 4A
Fuse F1 (A) (batteries input)
15A
24V operators outputs
2x 5A
2x 7A*
Warning:
The above values are calculated by taking the maximum power
supplied by the respective processors. In absolute terms, the maximum
current from each output must not exceed 10A.
Auxiliaries power supply output
24 V
(2 24V_ST =
max 200mA
)
Safety devices power supply output
“Warning” output
+24 V
max 15 W
Electric lock output
24V
max 5W or max
1 art. 110
Flashing light output
24 V
max 15W
Operating temperature range (°C)
-20÷50 °C
Receiver frequency
433,92 MHz
Transmitters type of coding
HCS
fi
x-code - HCS rolling
code - Dip-switch
Max remote controllers managed
100
* Values for STOP with boom
≥
6 m.
NET230N
Power supply (V)
230 V ~ ±10% (50/60 Hz)
Fuse F2 (A)
5A
Fuse F1 (A)
160mA
230V operators outputs
2 x 600W
Auxiliaries power supply output
24 V ~
(2 24V_ST
=
max 200mA
)
Safety devices power supply output
24V
“Warning” output
230 V ~ max 150W
Electric lock output
max 1 art. 110 or 24V
output max 5W con
fi
gurable
230V Flashing light output
230 V ~ max 40W
24V Flashing light output
24 V
max 100mA (for led
fl
ashing light) art. AURA N
Operating temperature range (°C)
-20÷50 °C
Receiver frequency
433,92 MHz
Transmitters type of coding
HCS
fi
x-code - HCS rolling code -
Dip-switch
Max remote controllers managed
100
OPERATOR
STOPNET/N/L-F
STOP24NET/N/V-F
STOP24NET/N/L-F
4÷6m
>6m
4m
4÷6m
>6m
Motor power supply voltage (V)
230 V ~ ±10% (50/60 Hz)
24 V
Absorbed power (W)
500
120
Type of boom used
Refer to Table on page I-7
Duty cycle (cycles/hour)
150
125
500
250
170
Maximum n° of operations in 24 hour
800
500
1500
1000
800
Built-in capacitor (
μ
F)
18
-
Operating temperature range (°C)
-20÷50
Motor thermal protection (°C)
150
-
Opening time 90° (s)
6,5
8
2,7
5,3
7,5
Weight of product with package (Kg)
81
79
Protection degree
IPX4