47 /87
To change the Audio Low level, press the OK key to enter the program mode (blinking arrow in
second row on the right). Press UP or DOWN keys to select desired value. Press OK key to confirm
or ESC key to exit routine without saving.
MIN value: -20 dBu
MAX value: +20 dBu
STEP: ±0.1 dB
Table 5.17 – Audio Low Level permitted values
To setup the timeouts Audio Low T1 and T2 navigate to the relative menus with UP or DOWN
keys.
Fig. 5.42 – Audio Low timeout menus
To change the Audio Low timeouts, press the OK key to enter the program mode (blinking arrow in
second row on the right). Press UP or DOWN keys to select desired value. Press OK key to confirm
or ESC key to exit routine without saving.
MIN value: 0 sec
MAX value: 1000 sec
STEP: ±1 sec
Table 5.18 – Audio Low timeouts permitted values
To disable this warning/alarm set both the timeouts Audio Low T1 and T2 to 0 sec.
5.3.7.6
AUDIO OVER EVENT
The Audio Over warning/alarm is generated if the audio level at an active input channel exceeds a
threshold set in the menu Audio Over Level for at least T1 seconds.
In presence of Audio Over warning/alarm in case the audio level drops below the Audio Over
threshold for at least T2 seconds the warning/alarm status is automatically ended. This
warning/alarm is indicated also by the led NO AUDIO switched on in the frontal panel.
The timeouts T1 and T2 are set in the menus Audio Over T1 and Audio Over T2.
Fig. 5.43 – Audio Over Level menu