34 /87
5.3.4.3
LIMITER REGULATION
In these sub-menus an upper limit for the output signal deviation can be enabled and regulated.
The menu Limiter permits to enable or disable the limiter, if the limiter is enabled the value can be
regulated in the next menu.
Fig. 5.23 – Enable limiter menu
To enable/disable the limiter press the OK key to enter the program mode (blinking arrow in second
row on the right). Press UP or DOWN keys to select the on/off state. Press OK key to confirm or
ESC key to exit routine without saving.
In case the Limiter is enabled the green led LIM on the frontal panel will switched on.
To adjust the limiter value, press DOWN key to select the Limiter value sub-menu.
Fig. 5.24 – Limiter value menu
To change the limiter value, press the OK key to enter the program mode (blinking arrow in second
row on the right). Press UP or DOWN keys to select the new value. Press OK key to confirm or
ESC key to exit routine without saving.
The limiter value is applied in real time and only if the limiter is enabled.
MIN value: 30 KHz
MAX value: 180 KHz
STEP: ±1 KHz
Table 5.5 – Limiter permitted values