8
CHAPTER 2.
INTRODUCTION
2.2.
When the server is dead
Obviously, fixing hardware defects is not possible using a remote management device. Nevertheless
LARA gives the administrator valuable information about the type of a hardware failure.
Serious hardware failures can be categorized into five different categories with different chances to
happen
2
:
1.
Hard disk failure
50%
2.
Power cable detached, power supply failure
28%
3.
CPU, Controller, main board failure
10%
4.
CPU fan failure
8%
5.
RAM failure
4%
Using LARA, administrators can determine which kind of serious hardware failure has occurred
(see Table
2.1
).
Table 2.1.: Host system failures and how they are detected
Type of failure
Detected by
Hard disk failure
Console screen, CMOS set-up information
Power cable detached, power
supply failure
Server remains in power off state after power on command
has been given.
CPU Controller, main board
failure
Power supply is on, but there is no video output.
CPU fan failure
By IPMI or server specific management software
RAM failure
Boot-Sequence on boot console
2
According to a survey made by the Intel Corp.
Summary of Contents for LARA
Page 1: ...LARA Installation and User Guide...
Page 4: ...iv...
Page 8: ...viii Contents...
Page 12: ...xii List of Tables B 1 LARA Video Modes 67 C 1 Key Names 69...
Page 30: ...18 CHAPTER 4 CONFIGURATION...
Page 74: ...62 CHAPTER 5 USAGE...
Page 76: ...64 CHAPTER 6 FREQUENTLY ASKED QUESTIONS...
Page 78: ...66 APPENDIX A GLOSSARY...
Page 80: ...68 APPENDIX B LARA VIDEO MODES...
Page 86: ...74 APPENDIX D PIN ASSIGNMENTS...