6
Installation must be done in accordance with any local regulations.
The chlorinator is designed only to run at the flow rates specified. In some instances flow may be too high
and so a bypass valve will need to be installed to reduce the flow through the cell as below.
To maximise pump efficiency, all plumbing should be completed using 40 or 50mm (1.5 or 2”) PVC pressure
pipe. The installer must ensure the chlorinator is provided with adequate support, especially where
interconnecting pipe work is unsupported. The dry weight of the unit is 6.6kg (14.6lbs).
LOCATION AND MOUNTING
Select a convenient location to mount the chlorinator. The display screen can be difficult to read in direct
sunlight, so a shaded area is recommended. The chlorinator must be kept away from chemical storage
areas, including acid and direct heat sources.
This diagram is intended to conform to the safe operation of saline chlorinators. Any deviation is
at the installer’s risk and may void warranty.
Note: The chlorinator must be positioned on the return to pool line after all accessories such as
the pump, heater and filter, but before the pipe work divides if there is more than one return to the
pool. Ozone generators must be installed after the discharge side of the chlorinator. (Failure to do
this may cause damage to the cell and void warranty)
WARNING:
The chlorinator contains electronic components which may become damaged if the unit is dropped.