background image

28

Davey

®

 Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction within 
warranty periods beginning from the date of original purchase due to faulty materials or manufacture, Davey 
will at our option repair or replace it for you free of charge, subject to the conditions below.

Should you experience any difficulties with your Davey product, we suggest in the first instance that you 
contact the Davey Dealer from which you purchased the Davey product. Alternatively you can phone our 
Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or send a written 
letter to Davey at the address listed below. On receipt of your claim, Davey will seek to resolve your 
difficulties or, if the product is faulty or defective, advise you on how to have your Davey product repaired, 
obtain a replacement or a refund.

Your Davey Guarantee naturally does not cover normal wear or tear, replacement of product consumables 
(i.e. seals, bearings or capacitors), loss or damage resulting from misuse or negligent handling, improper 
use for which the product was not designed or advertised, failure to properly follow the provided installation 
and operating instructions, failure to carry out maintenance, corrosive or abrasive water or other liquid, 
lightning or high voltage spikes or unauthorized persons attempting repairs. Where applicable, your Davey 
product must only be connected to the voltage shown on the nameplate.

Your Davey Guarantee does not cover freight or any other costs incurred in making a claim. Please retain 
your receipt as proof of purchase; you MUST provide evidence of the date of original purchase when 
claiming under the Davey Guarantee.

Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or 
injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation does not 
apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey 
product under the Australian or New Zealand legislation and does not affect any rights or remedies that may 
be available to you under the Australian or New Zealand Consumer Legislation.

In Australia, you are entitled to a replacement or refund for a major failure and for compensation for any 
other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if 
the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Should your Davey product require repair or service after the guarantee period; contact your nearest Davey 
Dealer or phone the Davey Support Centre on the number listed below.

For a complete list of Davey Dealers visit our website (davey.com.au) or call:

*  Installation and operating instructions are included with the product when purchased new. 

They may also be found on our website.

AUSTRALIA
Davey Support Centre

6 Lakeview Drive,

Scoresby, Australia 3179

Ph: 

1300 232 839

Fax: 

1300 369 119

Website: davey.com.au

Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517

NEW ZEALAND
Davey Support Centre

7 Rockridge Avenue,

Penrose, Auckland 1061

Ph: 

     0800 654 333

Fax:         09 527 7654

Website: daveynz.co.nz

™ Davey is a trademark of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2014.

Davey Guarantee Period

Chlorination Cell – Three (3) Years or 10,000 operating hours 

(whichever comes first), 2 Years all other parts & 1 Year Labour

P/N 402147

Summary of Contents for ProMatic 24

Page 1: ...Salt Water Chlorinator Patent Protected Installation Operating Instructions ProMatic Please pass these instructions on to the operator of this equipment...

Page 2: ...Connecting the Power 7 Connecting Peripherals Auxiliary Equipment 8 Replacing an Existing Power Source Cell 10 Pre Start Up Procedure 11 Features of Your Chlorinator 11 Cell Production 12 Operating y...

Page 3: ...the chlorine output to drop Once enough salt is added to the pool this warning message will vanish 2 MONITOR THE CHLORINATOR Davey recommends regular monitoring of your chlorinator for optimum perfor...

Page 4: ...7 This unit is to be installed in accordance with these installation instructions and any local Electrical Codes and the requirements of the authority having jurisdiction 8 The chlorinator must be pos...

Page 5: ...on page 26 in this manual can be used for location of drill entry points PREFERRED PREFERRED The interface display screen can be rotated by no more than 90 by hand to suit the installation orientatio...

Page 6: ...nt the chlorinator The display screen can be difficult to read in direct sunlight so a shaded area is recommended The chlorinator must be kept away from chemical storage areas including acid and direc...

Page 7: ...t on the chlorinator Its maximum current must not exceed 9A 2000W refer to the pump s technical nameplate to confirm Outside of these regions the pool pump must be connected to an external timer or co...

Page 8: ...alian New Zealand Standard AS NZS 4755 3 2 which concerns the operation of pool pump controllers for commands transmitted via your electricity provider During installation by wiring your smart meter o...

Page 9: ...s to the chlorinator mains power must be disconnected Wires sized AWG 26 gauge 21 gauge 0 1 0 4mm can be used Wires are routed through the panel as shown below A foam seal is provided to allow wires e...

Page 10: ...ngled 50mm elbow this is to ensure that the elbow does not protrude past the width of the original cell then glue this straight onto the side pipe as shown Measure down 250mm from the centre of the 90...

Page 11: ...l timer or controller ensuring that the pool filter pump is always on when the chlorinator is in operation MANUAL TIMER OPERATION Manual mode allows you to manually start and stop chlorine production...

Page 12: ...nator provides a guide to your pool salt levels and displays a LO OK or HI Salt Level reading This allows you to optimise chlorine production and maximise your cell life by ensuring your salt levels a...

Page 13: ...functions and settings one at a time RUNNING THE CHLORINATOR FOR THE FIRST TIME When running the chlorinator for the first time only you ll be prompted to select the interface language pool size and c...

Page 14: ...100 of the pool size maximum output for a 24 hour period before reverting back to either Timer or Manual mode operation When in Boost Mode the LCD display screen will say Boost Mode On The Manual Mod...

Page 15: ...wn will change the pool size in 10kL increments The minimum pool size is 5kL 1 3kgal and the maximum pool size is 125kL 33 0kgal If you are using the chlorinator on an even larger pool please set the...

Page 16: ...me is needed repeat Step 3 and press the Backwash Filter button again Step 4 Once the filter pump is off adjust the media filter valve to the Rinse position and press the Backwash Filter button again...

Page 17: ...l and wired via a micro switch to the terminal block provided in the back of the chlorinator unit the chlorinator will automatically reduce the chlorine output to 20 Once the pool cover is applied and...

Page 18: ...the pool and amount of sunlight exposure can all affect the minimum daily run time Please refer to the Chlorine Production section for more details Timer 1 Press Timer 1 button once Timer 1 Start wil...

Page 19: ...essential in helping to retain chlorine in your pool Chlorine is rapidly dissipated by sunlight and the use of stabiliser will reduce this loss substantially Without stabiliser it may be necessary to...

Page 20: ...as fertilisers and ground water runoff They can make algae control more difficult and increase the amount of sanitiser required If you are having trouble controlling algae and maintaining an adequate...

Page 21: ...orine levels For the chlorinator the output is limited to 24 grams per hour Pool Size kL 5 10 15 20 25 30 35 40 45 50 55 60 65 Cold 20 C 68 F 1 2 2 1 3 1 4 1 5 0 6 0 7 0 8 0 8 9 9 9 10 9 11 8 12 8 Tem...

Page 22: ...of the pool water within a 24 hour period If the level is too low either increase the cell production percentage or set a longer run time For variable speed and low speed pumps the run time will have...

Page 23: ...hat the chlorinator is mounted in a well ventilated and shaded location Allow some time for the unit to cool down before pressing the manual or timer mode buttons to resume chlorination C1 Chlorinatio...

Page 24: ...ump not plugged in or faulty Another fault has stopped chlorination Display is on but not responding Restart the unit if this problem reoccurs please contact your dealer for service Display is not tur...

Page 25: ...urine perspiration or other external elements Chloramines can cause eye and skin irritation as well as producing unpleasant odours Chlorine Demand The amount of chlorine required to destroy germs alg...

Page 26: ...26 35mm 1 3 8 80mm 3 5 32...

Page 27: ...27 NOTES...

Page 28: ...de evidence of the date of original purchase when claiming under the Davey Guarantee Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of...

Reviews: