INSTALLATION INSTRUCTIONS
Please note that the installation area should be well ventilated and free of substances that cause corrosion
such as fumes from concentrated chemical chlorine, acid and so forth. Failure to ensure a well ventilated
area may result in damage to the electronics, voiding warranty.
The chlorinator can be mounted in two orientations as shown below, with flow in either direction as indicated
by the arrows. Flow rates through the chlorinator should be kept within 80 to 400 LPM (21.5 to 106gal/m).
The chlorinator comes with 2 x 50mm (2”) barrel unions and a mounting bracket suitable for all orientations.
If using the mounting bracket, first mount the bracket to back of the cell housing with the screws provided. A
template provided, on page 26, in this manual can be used for location of drill entry points.
PREFERRED
PREFERRED
The interface display screen can be rotated by no more than 90°, by hand, to suit the installation orientation.
The chlorinator must not be installed in any other orientation or at any angle other than horizontal or vertical.
Such an installation will void your warranty.
Variable speed pool pumps, pipe restrictions and undersized or clogged filters can cause very low flow
rates through the chlorinator. Excessive air accumulating in the cell may cause the unit to cease chlorine
production in order to prevent damage to the equipment. If this occurs, the pump, filter or pipe work will have
to be adjusted, cleaned or changed before normal operation can resume.
Note: In certain installations, the flow rate may be insufficient to fill the cell housing completely
with water. In these cases the flow must be increased to ensure that the housing is completely full.