FUNCTIONALITY OF YOUR CHLORINATOR (CONT)
BACKWASH FILTER
The backwash filter function is used when you need to backwash, rinse and clean your media filter to waste.
It runs the filter pump during back wash mode and reduces the chlorine output to 0%. The filter pump will run
for a maximum of 2 minutes on each cycle.
Step 1.
Press the Backwash Filter button once, this will turn the chlorinator and filter pump off.
Step 2.
The LCD display screen will show Change Valve. Turn your media filter valve to the Backwash
position.
Step 3.
Press the Backwash button again this will start the filter pump. The LCD display will show
Pump
Running
. After 2 minutes the filter pump will switch off. The LCD display screen will show
Change
Valve
.
(If a further 2 minute backwash cycle time is needed, repeat Step 3 and press the Backwash
Filter button again).
Step 4.
Once the filter pump is off, adjust the media filter valve to the Rinse position and press the
Backwash Filter button again. The LCD display screen will show Pump Running. After 2 minutes
the filter pump will switch off. The LCD display screen will show Change Valve. (If a further 2 minute
rinse cycle time is needed, repeat Step 4 and press the Backwash Filter button again).
Step 5.
Once the pump is off and you have completed the backwash cleaning cycle, turn your media filter
valve back to the Normal filter operating position.
Step 6.
Press the Manual or Timer Mode function button to return to normal operation. This will turn the
chlorinator and filter pump back on.
Change Valve
4:00
PM
Pump Running
4:05
PM
Note: During this process the Cell Off, Timer & Manual Mode LED lamps will flash
simultaneously to worn the end user. Steps (1, 2, 3 & 5) can also be used for backwashing
excess water to waste.