14
FUNCTIONALITY OF YOUR CHLORINATOR
CELL OFF MODE
Pressing the Cell Off button turns the filter pump and chlorinator cell off. In this mode no chlorine will be
produced.
TIMER MODE
Pressing the Timer button starts timer operation. Timer mode automatically runs the chlorinator cell and
pump during the set timer periods. Make sure you have set up the timers before running in this mode (see
Setting the Timers below).
MANUAL MODE
Pressing the Manual / Boost Mode button once will run the chlorinator cell and pump independently of the
timer settings. When left in this mode, the chlorinator will run continuously.
BOOST MODE
You can choose the Boost Mode by pressing the Manual / Boost Mode button twice. This will run the unit at
100% of the pool size maximum output for a 24 hour period before reverting back to either Timer or Manual
mode operation. When in Boost Mode the LCD display screen will say Boost Mode On. The Manual Mode
LED lamp will flash during the 24 hour Boost period.
CELL PRODUCTION
Pressing the Cell Production button allows you to control the rate of chlorine production over the daily run
time (filtration period). Pressing the up and down buttons will change the output in 1% increments. Holding
either button down will change the output in 10% increments. The lowest allowed output is 5%, although 0%
can be selected to run the pump (with the cell off) if extended filtering times are required.
Refer to the
Chlorine Production
section for important information on how to maintain your chlorine levels.
Boost Mode On
2:30
PM
Output
100
%
Note: You can go back to either Manual or Timer mode at anytime by pressing the desired
function button.