Functions and Features:

 

• Adjustable CO2 output from 15 – 45 cubic feet per hour.
 • Water-cooled design removes 86% of the heat produced.
  • Adjustable water flow valve.
   • High / low gas setting.
    • Compact, wall-mount or suspended design.
     • Water activates the unit.
      • No flow / no go switch cuts off flame if water flow stops.
       • Auto-cut off protection for gas leaks and tipping over.
        • Overheat shutdown sensor.
         • Oxygen depletion sensor
          • Over pressure protection.
           • All copper water passages.
            • Inline water debris screen.
             • 1 year warranty with great service.
              • Optional valve for hooking unit directly to

                  pressurized municipal water supply.

Summary of Contents for hydrogen1

Page 1: ...ed design removes 86 of the heat produced Adjustable water flow valve High low gas setting Compact wall mount or suspended design Water activates the unit No flow no go switch cuts off flame if water flow stops Auto cut off protection for gas leaks and tipping over Overheat shutdown sensor Oxygen depletion sensor Over pressure protection All copper water passages Inline water debris screen 1 year ...

Page 2: ...leaks Applying soapy water over the joints will tell you right away if there is a leak Attaching Water Hoses Snugly screw both supplied hose barb adapters onto the water inlet and outlet MAKE SURE THE RUBBER GASKET IS INSTALLED Attach ID HEAVY DUTY REINFORCED TUBING to the hose barbs and install hose clamps Cold water inlet should be clearly marked along with the hot water outlet Installing Batter...

Page 3: ... WATER CHILLER COOLING METHOD TO PROPERLY SETUP YOUR SYSTEM IMPORTANT NOTE CHILLER WALL WATER CHILLER COOLING METHOD WATER CHILLER COOLING METHOD CO2 NEEDED PER HOUR RESERVOIR SIZE CHILLER SIZE 1 to 1 5 cubic ft hr 20 40 Gallon 1 10th hp 1 5 to 4 5 cubic ft hr 40 70 Gallon hp chiller 4 5 to 9 cubic ft hr 70 100 Gallon hp chiller 9 to 17 cubic ft hr 100 150 Gallon 1 hp chillers Reservoir And Chille...

Page 4: ...er discharge of the HydroGEN to be the most effective This would be recommended for someone that uses the HydroGEN more than 30 minutes an hour since it is only cooling while water is flowing through the HydroGEN unit Closed Loop You can use a secondary submersible pump in your reservoir that s connected directly to the heat exchanger and exits back to your reservoir Doing so this allows for const...

Page 5: ... To Waste Storage Reuse HOT CO2 MONITOR Another efficient cooling method is to circulate cool water from a large reservoir used outside your grow room Barrels plastic tubs and even small above ground swimming pools can be bought for less than 75 and make excellent reservoirs During the off cycle the reservoir is allowed to naturally cool down so obviously this idea works great for cooler areas LAR...

Page 6: ...J Heat A Hut B CO2 Generator C Reservoir and Pump D Chiller or Heat Exchanger E CO2 Duct F Wall G Water Inlet H Water Outlet I CO2 J Heat A Hut B CO2 Generator C Reservoir and Pump D Chiller or Heat Exchanger E CO2 Duct F Wall G Water Inlet H Water Outlet I CO2 J Heat B F G H C D J I IN ROOM DIAGRAM B F E G H C D J I A HUT DIAGRAM ...

Page 7: ...ARFROMTHEUNITASPOSSIBLE THISISWHYYOUWERESUPPLIEDA12 HOSE WATERFLOWMUSTEXCEED1 5GPMAND3PSIFORTHEHYDROGENTOOPERATE DON TUSEAGINGORCRACKINGHOSES Troubleshooting Unit does not light Check propane level don t be fooled bottles are heavy even when they are empty Check propane valve and make sure it s on Check the batteries and make sure they are installed properly Replace batteries if it s possible they...

Page 8: ...14 15 ...