4 INSTALLATION
Operating instructions
FEATURE
SPECIFIC
Operating temperature
0°C ... +50°C
Cooling
Ventilate the drive in case of continuous operation
Operating humidity
95% relative or lower humidity (without condensation)
Storage temperature
-20°C ... +70°C
Storage humidity
95% relative or lower humidity (without condensation)
Place of installation
Free of corrosive gases
Free of dust and iron powder
Not subject to moisture or lubricating oil such as cutting oil
Altitude
1,000 m or less
Vibration resistance
4,9 m/s2
Shock resistance
19,6 m/s2
Operating conditions
Installation category (overvoltage category): III
Pollution degree: 2 or better
Protection class: IP3X (EN50178)
Place of installation
Installing in a control panel
Design the control panel size, module layout and cooling
method so that the temperature around the drive does not
exceed 50 ° C. Note: To increase product life and maintain
reliability, keep the temperature inside the control panel
below 40 ° C.
Installation near a heating
module
Minimize thermal radiation from the heating module and any
temperature rises caused by natural conversion, so that the
temperature around the drive does not exceed 55 ° C.
Installation near a vibration
source
Install a vibration damper below the drive to avoid subjecting
it to excessive vibration.
Installation in a place
exposed to corrosive gases
Corrosive gases do not have an immediate effect on the
device but, in the long term, cause malfunctions of the
electronic components. Take appropriate measures to avoid
the presence of corrosive gases.