The digital outputs are protected against overloads (Max 500mA) and short-circuits; in case of
overload the output will switch off until the anomaly is removed.
If inductive loads, such as relays, solenoid valves, etc. have to be driven, connect a flyback diode in
parallel to the load.
ATTENTION
5 CONNECTION DIAGRAM
Typical connection
Stepper Motor Drive
SMD1204L_SSP
+HVdc
Common
GND
24Vdc
GND
Drive mod.
DMD1204xIxx
M1.9
M1.8
M1.7
M1.6
M1.5
M1.4
M1.3
M2.1
M2.2
M2.28
M2.29
M2.3
M2.4
M2.6
M2.7
+
Common
AC/DC
supply
0V
24Vdc
+
Common
AC/DC
supply
0V
+HVdc
Green Ch.A-
Blue Ch.B+
White Ch.B-
Brown +5V
SSP1
SSP2
Red GND
Yellow Ch.A+
Black + Motor
Orange - Motor
Ferrite
Ground
screen
Connect together all the common power supplies and signals, present in the terminal blocks.