Operating instructions
4.1 Panel installation
If installed inside an electrical panel, leave a free space of at least 50 mm around the module in case
of the installation of a single drive. If more drives are installed, respect the minimum space, as shown
in the following figure, between two contiguous drives, in order to guarantee air flow and cooling of
the modules.
Do not cover the ventilation slots and prevent foreign bodies, such as metal fragments,
liquids or combustibles, from entering the product.
It is expressly forbidden to undertake actions aimed at modifying any mechanical part of
the drive.
Failure to observe this warning can cause internal components to deteriorate, resulting in fires or malfunctions.
ATTENTION
50mm min
(1.97 in min)
50mm min
(1.97 in min)
50mm min
(1.97 in min)
20mm min
(0.78 in min)
Ingresso flusso
dʼaria
Uscita flusso
dʼaria
OUTLET
AIR
INLET
AIR