MAINTENANCE AND CARE
Checking the fuse of the rechargeable battery and of the charger
ATTENTION
When checking or replacing the fuses:
- the rechargeable battery must be switched
OFF,
- the power plug of the charger must be un-
plugged.
Do never use a stronger fuse or repair the fuse.
Incorrect or improper handling can damage the
whole electrical system!
If the fuse blows up without an apparent reason,
please consult your daum electronic dealer.
NOTE
Use the following fuses for replacement:
Rechargeable battery (3)
F 30A L 250V
Rechargeable battery (2)
5A 250V
Charger (5)
T 10A L 250V
Replacing the fuse
- Open the cover (1 or 2) on the rechargeable bat-
tery or (4) on the charger.
- When replacing the fuse make sure it is well
seated. Loose fuses will blow up.
- Complete the installation in the opposite se-
quence.
72
ergo_bike pedelec
4
3
5
1
2