Changes to the camera settings can be made via the “Settings” menu selection, and the settings
are stored in the registry and restored the next time the application is run. The Digital Still
Camera settings include:
Setting Selections
Available Description
of
Setting
Brightness
-2.0 F-stops to +2.0 F-stops
Controls the amounts of light during exposure. The larger the F-stop,
the more bright the image will appear.
Capture Size
2048 x 1536 (3.2M pixels)
1632 x 1232 (2.0M pixels)
1280 x 1024 (1.3M pixels)
800 x 600 (480K pixels)
640 x 480 (307K pixels)
Used to select the size of the snapshot image to acquire. Values indicate
the height and width of the image in pixels.
Contrast
Automatic, OFF,
10% - 100% in increments of
10%
This setting is used to adjust the visual properties of an image that
makes an object in an image distinguishable from other objects and the
background.
Flash Mode
Automatic, OFF, Always ON
Used to specify the flash (illumination) operation when taking snapshot
images.
Flash Intensity Still Mode
25% to 100% in increments of
25%
Controls the intensity of the flash when taking snapshots.
Flash Intensity Preview
Mode
25% to 100% in increments of
25%
Controls the intensity of the flash when previewing a scene prior to
taking a snapshot.
Flicker Cancellation
OFF, 50 Hz, 60 Hz
Improves image quality when the camera is used in an environment
containing fluorescent lighting. Flickering of fluorescent lighting is
caused by alternating current reversals occurring 50 to 60 times a
second.
Preview Illumination
Mode
ON, OFF
Specifies whether or not to use flash illumination during preview mode.
Preview Size
320 x 240, 160 x 120
Used to select the size of the preview image displayed on the DSV2+
screen. Values indicate the height and width of the preview image.
Sharpness
Normal, Less Sharp, More
Sharp
This setting softens or sharpens areas in the image where an edge
changes from one brightness level to another.
White Balance
Automatic, Sunlight, Outdoor
shadow, Fluorescent, Tungsten,
LED
Controls the process of removing unrealistic color casts, so objects
which appear white in the scene being captured are rendered white in
the photograph. Specify the setting closest to the environment in which
the snapshot is being taken.
Zoom
x1, x2
Used to provide the equivalent of two lenses with different focal
lengths. X1 is normal operation, X2 is the “zoomed” mode.
7.5 Scanner (PA & SW) Test Demo (DsVerifyScanTestAsync.exe)
This application can be used to optically scan and save documents and also allows the decoding
technology to be invoked by the use of a menu. To close the application click File/Exit.
Scanner Screen
•
Reset –
Resets the scanner subsystem. The message on
the bottom of the display should say “Scanner Idle”.
•
Auto Wait for Doc., Scan Image
– This is the default
setting.
o
After starting the application, the message on the
bottom of the display should say “Waiting for
Scan”
o
After scanning a document the message should
read “Scanner Idle w/Image”. You must now
specify to the scanner what type of document you
want to decode and where you want to decode it.
See Decoder Screen options below.