background image

DSV2+

Turbo

 User Manual, Version 1.09 

50 

Copyright 

© 

2006 by Datastrip, Inc.  All rights reserved.   

Reproduction in whole or in part is prohibited. 

Compress: 

The compress option should be used to do decoding on the Host processor or to do document 
archiving.  The option will compress .BMP files to .JPEG making the file size smaller and the 
internal file transfer faster.  

 
Calibrate: 

The default for this option is “Normalize” (calibrate box unchecked). 

In Normalize mode the DSP looks for the darkest and lightest spots on the whole image and then 
balances the image.   

In Calibrate mode the DSP for the darkest and lightest spots on a row by row basis.  This mode is 
slower but sometimes helpful for problematic (“noisy”) images. 

 

Wait Timeout: 

The Wait Timeout is the time, in seconds, that the scanner subsystem will wait for a document to 
be scanned before restarting the scanner subsystem. 

 

Summary of Contents for DSV2+Turbo

Page 1: ...Part Number 4207 00008 109_0A DSV2 T urbo User sManual GSA Approved NIST FIPS 201 SP 800 76 Compliant ...

Page 2: ...tes Copyright Act without the prior written permission from Datastrip Requests to Datastrip for permission should be addressed to Datastrip Inc 211 Welsh Pool Road Suite 100 Exton PA 19341 1321 USA or Datastrip Ltd Unit 7 Thame Park Business Centre Wenman Road Thame Oxon OX9 3XA UK Acknowledgements DSV2 Turbo is a registered trademark of Datastrip Windows and WinCE are registered trademarks of Mic...

Page 3: ...AN Ethernet Port 10 4 4 4 Smart Card Slot 10 4 5 Serial Port 11 4 5 1 Serial Port Electrical Specifications 11 4 6 Dual Grip Battery Cover 11 4 7 Digital Still Camera 11 4 7 1 Digital Still Camera Installation Instructions 12 5 Battery Charging and Replacement 13 6 Basic Operation 15 6 1 System Startup Sequence 15 6 2 Stylus 15 6 3 Touch Screen Adjustments 15 6 4 Input Panel Keyboard 16 6 5 Creati...

Page 4: ...tes 33 9 DSV2 Turbo SC Product Specifications GSA FIPS 201 Compliant 34 10 Regulatory Compliance Statement 35 11 Fingerprint Algorithms and Support 36 12 Troubleshooting 36 13 Available Parts Supplies and Accessories 37 14 Service Support 40 15 Appendix A Docking Station 41 15 1 1 Adjusting the Docking Station Backrest 41 15 1 2 Dual Grip Tethered Stylus 41 16 Appendix B Active Sync 42 16 1 Active...

Page 5: ...l Version 1 09 5 Copyright 2006 by Datastrip Inc All rights reserved Reproduction in whole or in part is prohibited 17 Appendix C Scanner Information 48 17 1 Scanner Settings 48 17 2 DSV2 Turbo PA Product Specifications 51 ...

Page 6: ...nsor using 1 to 1 or 1 to N fingerprint matching algorithms The DSV2 Turbo is applicable for programs such as USVISIT Transportation Worker ID Card TWIC Common Access Card CAC and many other ID card scenarios The basic DSV2 Turbo product comes from the factory with a Windows CE NET Version 5 00 Operating System software utilities and some demo and sample applications When the unit is activated a s...

Page 7: ...the shipping box in the event you need to return your product for service 3 Initial Setup Each unit is shipped with one Lithium Polymer battery installed though disconnected To connect the battery you will need to remove the rear battery access cover and plug the battery connector into the mating connector on the left hand side of the battery compartment It is recommended that you fully charge the...

Page 8: ...button too long will cause an error type beep sound and the system will not be powered up or down as the case may be This procedure helps to guard against accidental activation or shutdown of the system 4 2 Power LED Indications System State Power switch LED Comments Off not charging Off Off charging Red Unit is plugged into external power Green Release power button after first beep If power butto...

Page 9: ...hese steps Double tap My Computer and Select Storage Card DSVII Double tap the PPCalFt41utility and press the Calibrate button to re calibrate the fingerprint sensor This process may take up to a minute and then a green window with a number 1 should appear to indicate the sensor was successfully calibrated Double tap the DsVerifyFpCaptureTest application In the lower right hand corner select UPEK ...

Page 10: ...V2 supplies two standard USB ports Ver 2 0 compatible with either low speed 1 5 Mbps or full speed 12 Mbps devices These are host type ports compatible with peripheral devices only keyboard mouse etc DO NOT connect this host ports directly to other USB host devices such as a PC for these type applications use the mini USB client port Ver 2 0 4 4 3 10 100 LAN Ethernet Port The DSV2 features an Ethe...

Page 11: ...ry Cover which provides a more robust handgrip for better control under harsh conditions The Dual Grip Battery Cover is an alternative to the standard battery cover 4 7 Digital Still Camera The Digital Still Camera DSC is an optional module that is available for use with any of the DSV2 models It is a 3 2 Megapixel camera packaged in a mechanical module that replaces the standard battery cover of ...

Page 12: ...ion in whole or in part is prohibited 4 7 1 Digital Still Camera Installation Instructions Step 1 Remove the DSV2 battery door cover Step 2 Plug the camera cable into the battery compartment camera connector Step 3 Attach the camera housing to the DSV2 using the two captive screws Step 1 Step 2 Step 3 ...

Page 13: ... same whether the battery is charged with the unit On or Off 5 When a DSV2 terminal is left on the shelf in the Off state the battery will maintain its charge for over 6 months Description SC Capacity hours of use Scanner Capacity hours of use Charge Time for fully depleted battery Comments One 3000 mAh battery 5 5 hours N A 3 hours Under normal operating conditions the battery does not need to be...

Page 14: ... by Datastrip 1 CAUTION Battery has a risk of FIRE EXPLOSION or BURNS DO NOT short circuit the battery terminals crush puncture disassemble or otherwise damage the battery s case operate or charge at temperatures above 40ºC or store the battery at temperatures above 100ºC incinerate or immerse in water DISPOSAL Always consult and obey all international federal provincial state and local hazardous ...

Page 15: ...ag it across the screen to select text and images Drag within a list to select multiple items Tap and hold Tap and hold the stylus on an item for a short period until a menu displays a list of actions available for that item Tapping and holding is equivalent to right clicking your personnel computer mouse button When you tap and hold a circle of red dots appears around the stylus to indicate that ...

Page 16: ... 1 Power States Clicking the power schemes tab allows you to maximize battery life by programming the idle time for each of the following conditions 1 Fully On Every sub system is on and operational 2 User Idle Touch screen or Function keys haven t been used for some amount of time user configurable Backlight is dimmed to save power tap the screen and the backlight comes back on All other internal...

Page 17: ...ry The power LED is Green Æ Red flash Battery Levels The three battery levels that are color coded on the battery gauge 1 Green Battery charge is Good 2 Yellow Battery charge is Low 3 Red Battery charge is Very Low Critical As seen in the color coded pie chart below the three battery levels are not linear If this were the gas tank on your car then Yellow would be a quarter of a tank and Red would ...

Page 18: ...e are additional demonstration programs available as source code for custom software development in the Datastrip DSVII SDK sold separately 7 1 Software Version Utility DsVerify2About exe This utility reports the OS Version the versions of all Datastrip specific drivers and components software license settings the unit serial number and the HW Configuration To run this utility Click Start Run Clic...

Page 19: ...creen the following operations are available Clicking on the FP Settings button will open the fingerprint threshold setting screen Refer to the Fingerprint Settings Screen section below for details Clicking on the Scan Settings button will open the scanner settings screen Refer to the Scanner Settings Screen section below for details Clicking on the Timer Settings button opens the Display Timer Di...

Page 20: ...settings for a DSV2 PA The scanner parameters can be changed from this screen For details on the scanner settings please refer to Appendix B Section 17 1 Scanner Settings Clicking on the OK will save the settings and return the application to the Configuration Screen Clicking on the Cancel or the X will abort any changes to the settings and return the application to the Configuration Screen Find D...

Page 21: ...e upper right corner of the application are used to close or terminate the application Clicking either of these buttons will shut down the application The CHUID Button The CHUID button will perform a number of tests on the card and extract the CHUID details Additionally it will check the configuration settings of the program and determine if the information stored in the card is to be accepted at ...

Page 22: ...the card This data can be used as necessary for auditing logging or advanced determination of qualifications Tapping the Printed info button will initiate the PIN procedure and after authentication provide the Printed info Display in the application The Biometric Button This button is used after pin authentication to extract the biometric template from the card This is for future expansion on the ...

Page 23: ... a snapshot After aligning the subject in the display pressing F1 will turn on the preview illumination if selected in the settings and then pressing F1 a second time will capture and save the target image If the preview illumination is not configured pressing F1 once will capture and save the target image Digital zoom can be controlled via the Settings menu or by using the F2 and F3 buttons F3 X2...

Page 24: ...ing Flickering of fluorescent lighting is caused by alternating current reversals occurring 50 to 60 times a second Preview Illumination Mode ON OFF Specifies whether or not to use flash illumination during preview mode Preview Size 320 x 240 160 x 120 Used to select the size of the preview image displayed on the DSV2 screen Values indicate the height and width of the preview image Sharpness Norma...

Page 25: ...ame and location and then shows the image on the display Auto Upload Image to Memory When checked this option takes the scanned image uploads it to the Host Processor memory and shows the image on the display Wait for Doc Scan Upload to M When doing repetitive operations this non persistent option makes things easier by combining Wait for Doc Scan Image and Upload Image to Memory Wait for Doc Scan...

Page 26: ... is a dialog based application created to demonstrate ePassport scanning and decoding The ePassport is first scanned to read the Machine Readable Zone MRZ at the bottom of the ePassport This information contains a key that can then be used to open the contact less Smart Card when presented to the DSV2 smartcard reader and to extract the biometric information for verification purposes The ICAO View...

Page 27: ... o Prevents copying SOD authenticates chip and proves that chip and physical passport belong together It can ensure that the chip is legitimate and issued by the country claimed Basic Access Control o Prevents skimming eavesdropping and misuse The e Passport cannot be read by an electronic reader until the machine readable zone is read first Results of AA and PA security features are displayed as ...

Page 28: ...ication is used to enroll and later verify user information on HID IClass Smart Cards This sample uses a PC SC driver developed by Datastrip to operate with an HID OEM 150 Smart Card reader when it is present in a system It captures both fingerprints and photos using the internal fingerprint imager and Digital Still Camera collects some sample demographic information and encodes this data onto 2K ...

Page 29: ...o looks for its authentication key when reading and writing to an IClass card f When all the boxes are filled Tap the button labeled Load This will attempt to load the key to the reader Any errors received or if the loading was successful will be displayed next to the label Last Result g To close this dialog tap the X in the upper right corner or tap the Ok button 3 Loading a key to a Card Note Lo...

Page 30: ...tration It can take up to a minute or two to complete this process Internally this program calls regsvrce exe to register each ActiveX control so that the interface presented by the ActiveX control will be available for application use This is usually followed by RegistrySaver exe or Suspend to make sure that the altered registry is written to flash memory for future use When this application is i...

Page 31: ...ate source file Ex Src File DSVII_0195_sh4 CAB Click Update This step will take approximately 2 5 minutes Click Reboot The registry will be cleared prior to shutdown Power Up unit The DSV2 registration program will automatically open Select the button for the device that you are registering DSVII SC DSVII PA or DSVII SW Select OK and wait This process will take from a few seconds Click Ok in the H...

Page 32: ...by installing runtime files of the proper form hex extension which have been generated by Datastrip Check that the Scanner Firmware provided is compatible for use with the unit by looking at the DSVII Software Release Notes for the Run Time software The version of the scanner firmware can be checked in the DatastripDsVerify2About application under the name ScanVer In the directory Storage Card DSV...

Page 33: ...are The procedure for updating the Digital Still Camera firmware is as follows In the directory Storage Card DSVII run the utility DSC_Firmware_update exe The application displays the current version number of the camera firmware and asks the question Do you want to update the camera firmware If you answer Yes then browse to the directory Storage Card DSVII DSVII_DSC_Firmware select the latest fir...

Page 34: ...W Environmental Characteristics Operating Temperature 0 to 40 C 32 to 104 F 50 C 120 F or higher at low RH Storage Temperature 20 to 60 C 4 to 158 F Relative Humidity 90 at 40 C Non condensing Drop Resistance Exceeds MIL STD 810F Regulatory Compliance Core System Safety CE Low Voltage Directive 72 73 EEC EN 60950 2000 EMC CE EMC Directive 89 336 EEC 93 68 EEC EN 55022 1998 EN 55024 1998 R TTE Comp...

Page 35: ...the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following mea...

Page 36: ...ally 1 n locally 1 N on host 3rd Party Integrated Proprietary ANSI 378 ANSI 381 Q3 06 Printrak 1 2000 locally in less than 15 secs NEC 1 1 locally 1 n locally 1 N on host 3rd Party Integrated Proprietary NEC 1 5000 locally in less than 1 second 12 Troubleshooting PROBLEM POSSIBLE REASON AND REMEDY Unit does not power up The battery may be not connected or may be completely discharged Open the batt...

Page 37: ...etter control under harsh conditions Works with all models DSVODGBC Digital Still Camera DSC Module 3 2M Pixel Color Camera Quick point and shoot use Seamlessly integrated into dual grip back cover Built in flash illumination Built in preview illumination Auto Exposure User configurable operation Demo application software included Full SDK support DSVODSC Docking Stations Works with all models Ope...

Page 38: ...C DSVSOW External Power Supply Line Cord Universal 90 240 VAC 50 60 Hz input DSVOACC P N 3090 01225 02 External Power Supply Cord Universal 90 240 VAC 50 60 Hz input P N 3008 60163 01 External power supply AC mains cord European These cables allow equipment fitted with a figure of 8 power connector to be plugged into a 2 or 3 pin European mains power socket NOT suitable for use in the UK 3008 9000...

Page 39: ...k ballistic nylon weave laminated with padding material on the inside Zipper access to insert remove DSV2 device Shoulder strap attachment D rings Cover flap to protect the front of the device when not in use Can be self stored when not needed or removed when not needed for long periods scanner models only Stylus pocket Serial DC power connectors remain accessible for user convenience DSVSCCB DSV2...

Page 40: ... upgrade or repairs please contact the tech support department by e mail or telephone An RMA will be issued and should be clearly marked on the outside of your shipping carton Please be certain to provide adequate shipping insurance to safeguard the contents For international shipments please include a declaration of value or other relevant legal documents that are required for shipment of this ty...

Page 41: ... insure proper operation i e serial connection between the DSV2 and the docking cradle Forward Position This position should be used for DSV2 Turbo Scanners or DSV2 Turbo SC terminals with the standard battery cover See Figures 1 and 2 Rear Position This position should be used for DSV2 Turbo Scanners or DSV2 Turbo SC terminals with a Dual Grip Battery Cover or a Dual Grip Camera Assembly See Figu...

Page 42: ...nd connect it to any one of the host PC USB ports using the USB 2 0 to Mini B cable After the DSV2 terminal has been connected Windows will notify you that it has Found New Hardware You will then be asked Can Windows Update search for new software Answer NO not this time The Wizard will then ask how you want to install software Answer Install the software automatically Recommended 16 1 3 Establish...

Page 43: ...u can reconnect the cable and start another ActiveSync session 16 2 4 Troubleshooting the Connection If a connection is not automatically established check the following The DSV2 will not connect while it is in Suspend mode Wake the DSV2 from Suspend prior to placing it in the docking station Verify that Serial via COM1 is selected on your terminal Go to the Control Panel and double click PC Conne...

Page 44: ...be asked Can Windows Update search for new software Answer NO not this time The Wizard will then ask how you want to install software Answer Install the software automatically Recommended 16 4 3 Establishing a Connection Each time you connect the DSV2 terminal to the host PC you will be asked if you would like to set up a Partnership If you will be using this DSV2 terminal on this PC regularly the...

Page 45: ...e DSVOSCAUSB Datastrip DSV2 _Turbo_USB Sync Setup utility found on the DSV2 User Manual CD 16 5 2 PC Configuration for USB 2 0 ActiveSync First Time Only Run the DSV2 _Turbo_USB Sync Setup utility found on the DSV2 User Manual CD After running the Sync setup you will be prompted to connect your DSV2 terminal to the PC Turn your DSV2 terminal on and connect it to any one of the host PC USB ports us...

Page 46: ...s selected Go to the Control Panel and double click PC Connection On this screen you should see USB via COM3 If not then click Change Connection Click the scroll bar arrow If you see the option for USB on COM3 then select it and click OK Click OK again to close the PC Connection screen Re insert your USB cable to get connected If you did not see the option for USB on COM3 your terminal is not USB ...

Page 47: ...nfigure the 802 11 adaptor on this screen and browse through to the tab WIRELESS INFORMATION Double click your wireless network Configure the adaptor as necessary to connect to the router Click OK Note that your network name in the list will display preferred Select your network from the list again and click Connect The status will change to Connected to YourNetworkName and the icon in the notific...

Page 48: ...ionally the same Scan Window Size DSV2 Turbo PA 3 36 81 mm DSV2 Turbo SW 1 15 27 mm The SW and PA both scan documents at up to 600 dpi in 8 bit grayscale with a user selectable illumination source of Near IR or RGB Visible light The default configuration of the scanner is to use RGB Visible light illumination since this setting works for a large percentage of document types However many travel doc...

Page 49: ...ines how far from the beginning of a document that the symbology ends Top and Bottom The parameters that define the width of symbology that will be scanned on a document Top defines the outside edge of the card guide and Bottom defines in the inside edge of the card guide The default scan regions are set to the maximum length and width as follows DSV2 Turbo PA DSV2 Turbo SW Left 0 inches Left 0 in...

Page 50: ...nternal file transfer faster Calibrate The default for this option is Normalize calibrate box unchecked In Normalize mode the DSP looks for the darkest and lightest spots on the whole image and then balances the image In Calibrate mode the DSP for the darkest and lightest spots on a row by row basis This mode is slower but sometimes helpful for problematic noisy images Wait Timeout The Wait Timeou...

Page 51: ...rage Temperature 20 to 60 C 4 to 158 F Relative Humidity 90 at 40 C Non condensing Drop Resistance Exceeds MIL STD 810F Regulatory Compliance Core System Safety CE Low Voltage Directive 72 73 EEC EN 60950 2000 EMC CE EMC Directive 89 336 EEC 93 68 EEC EN 55022 1998 EN 55024 1998 R TTE Compliance under EN 300330 EN 301489 03 NRTL TÜV Rheinland of North America Inc FCC Declaration This device compli...