11. Fingerprint Algorithms and Support
Fingerprint
Matching Vendor
Algorithm Matching
Mode
Support Type
Standard Supported / Notes
Identix BioEngine
5.0 or 3.0
1:1 locally
1:N on host
Fully Integrated
Proprietary
ANSI 378/ANSI 381 - Q3 06
Cogent
Ver 2.0.0.1
1:1 locally
1:N on host
Fully Integrated
Proprietary
Bioscrypt BioSDK
Ver 8.1
1:1 locally
1:N on host
3
rd
Party Integrated
Proprietary, “User Record Format” ANSI
INCITS 377-2004 Finger Pattern Data
Interchange
Agora
Ver 1.5
1:1 locally
1:N on host
Fully Integrated
Proprietary
Motorola 1:1
locally
1:n locally
1:N on host
3
rd
Party Integrated
Proprietary
ANSI 378/ANSI 381 - Q3 06
Printrak 1:2000 locally in less than 15 secs
NEC
1:1
locally
1:n locally
1:N on host
3
rd
Party Integrated
Proprietary
NEC 1:5000 locally in less than 1 second
12. Troubleshooting
P
ROBLEM
P
OSSIBLE REASON AND REMEDY
Unit does not power up
The battery may be not connected, or may be completely discharged.
¾
Open the battery access cover and verify that the battery is properly installed.
¾
Use the external AC power adapter to operate the unit and simultaneously
charge the battery.
Please refer to Section 0 “Battery Charging and Replacement”
Unit generates a single “error”
beep tone, and the power LED
flashes RED once
¾
This is an indication that the internal battery is very low, and does not have
sufficient charge to run the unit at all.
¾
Plug in the AC power adapter to charge the battery AS SOON AS POSSIBLE