DATAPROCESS EUROPE S.p.A.
ST 230 USER MANUAL Pag.
38
Press the
THERM TRANSF
key: the corresponding led lights
in Thermal Transfer, whilst when it is off is in direct thermal.
13.15.4
Enable/Disable of the photodispenser
sensor (optional)
Press the
ON LINE
key: the corresponding led indicated the
status.
NOTE: that there are two different status corre-
sponding to the photosensor abled, depending on the
further check of correct dispensing is excluded (first pression) or abled (second
pression).
Pressing
HEAD LIFT
key again, the selection stops and a test label is printed con-
taining the values set. At this point exit from configuration mode (as described in
paragraph 13.8) in order to execute the modifications programmed.
13.16 PARAMETER RESET
The printer parameters can be modified by the operator to adapt the printer to the
proper requirements, nevertheless in case the printer has been programmed with
the wrong parameters the operator has to follow the here below procedure to zero
them and return to standard parameters.
Select the printer in configuration mode (as described in paragraph 13.8 at point 1)
than press together the
THERM TRANSF
,
ON LINE
keys that reset the stored
parameters on the non-volatile memory of the printer.
+
The light leds will be off, than on and a test label will be printed with the standard
parameters of the printer.
Exit from configuration mode of the printer (as described in paragraph 13.8), switch
the unit off and on to execute the variation.
WARNING: Before executing the above procedure remember
to note the correct values of the printer
configuration.