Ch a pt e r 3 - Pr in t e r Ope r a t ion
2 9
Advanced Ent r y Calibr at ion ( cont inued)
St e p
Act ion
D ispla y e d M e ssa ge
Com m e n t
F
Use t he UP and DOWN Ar r ow
but t ons t o set t he Gain Num ber t o
00.
Recor d t he sensor r eading as a
Label Value for Gain Num ber 00 in
a t able ( 32 r ow s by four colum ns,
w it h headings sim ilar t o t hose
show n below .)
TRAN SENSOR GAI N
00
( 0 - 31)
This is t he Label Value for a gain
set t ing of 00.
Sam ple Calibr at ion Table
Gain Num ber
Label Value
TOF Value
Differ ence Value
00 252
01
02
…
31
St e p
Act ion
D ispla y e d M e ssa ge
Com m e n t
G
Use t he UP and DOWN Ar r ow
but t ons t o incr em ent t he Gain
Num ber by one and t hen Recor d
t he Label Value.
Repeat t his pr ocess for each Gain
Num ber .
TRAN SENSOR GAI N
01
( 0 - 31)
This is t he Label Value for a gain
set t ing of 01.
Sam ple Calibr at ion Table
Gain Num ber
Label Value
TOF Value
Differ ence Value
00 252
01 250
02 248
… …
31 09