Ch a pt e r 4 – M e n u Sy st e m
5 0
D I SPLAYED I TEM
I TEM D ESCRI PTI ON
FAULT HANDLI NG
Det er m ines t he int er v ent ion r equired and t he disposit ion of t he label in pr ocess
w hen a fault occur s, wher e:
LEVEL
Select s t he user act ion and t he r epr int st at us upon declar at ion of a fault , where:
NO REPRI NT
Pr int ing st ops and a fault m essage is displayed. Follow ing cor r ect ion of t he
pr oblem , t he FEED Key m ust be pressed t o clear t he fault , but t he label in pr ocess
is not r epr int ed.
STANDARD
Pr int ing st ops and a fault m essage is displayed. Follow ing cor r ect ion of t he
pr oblem , t he FEED Key m ust be pressed t o clear t he fault t hen t he label in pr ocess
is r epr int ed. ( Default Set t ing.)
VOI D AND
RETRY
Depending upon t he RETRY COUNT ( see below ) , one of t he follow ing occur s:
I f t he count has not been exceeded, VOI D is pr int ed ( see VOI D DI STANCE) on t he
failed label and r epr int ing aut om at ically occur s;
I f t he count has been exceeded, pr int ing st ops and a fault m essage is displayed.
Follow ing correct ion of t he pr oblem , t he FEED Key m ust be pressed t o clear t he
fault before t he label in process is repr int ed; or ,
I f t he CANCEL Key is pr essed, repr int ing is opt ional: t o r epr int pr ess NO; or , t o
cancel t he repr int pr ess YES ( and pr ess YES again t o cancel t he bat ch.)
( 1) Wit h no Linear Scanner at t ached, t he pr int er w ill per for m in
t he STANDARD set t ing, except t hat VOI D w ill be pr int ed on t he
fault ed label.
( 2) VOI D w ill not be pr int ed if insufficient t ext space exist s ( see
VOI D DI STANCE, below ) , or if t he fault occur r ed aft er pr int ing.
( 3) The t ex t can be cust om ized, see t he Pr ogr am m er ’s Manual
for det ails.
VOI D DI STANCE
Set s t he dist ance t o backup and t hen pr int VOI D on a fault ed label, w her e:
( 0.09 – 2.00
in.)
0.50
I s t he dist ance, m easur ed fr om t he t r ailing edge of t he label, which indir ect ly
est ablishes t he font size of t he t ex t . ( The default set t ing is 0.5 inches.)
RETRY COUNT
Set s t he num ber of r epr int at t em pt s, w her e:
( 0 – 3)
1
I s t he last label in t he count t o be voided before t he pr int er w ill st op and display a
fault m essage. ( The default set t ing is one.)
Ret r y count s gr eat er t han 1 ar e only valid for pr int er s equipped
w it h t he Linear Scanner or RFI D opt ion.
BACKFEED ON
CLEAR
Det er m ines t he pr int er 's act ion aft er a fault is clear ed, w her e:
ENABLED
Backup label posit ioning w ill occur aft er t he fault is clear ed.
DI SABLED
No backup label posit ioning w ill occur aft er fault clear ing; t he pr int er w ill assum e
t hat t he cur r ent posit ion is cor r ect . ( This is t he default set t ing.)
I f r eloading m edia, t he label m ust be placed it s pr esent ed
posit ion.
SCL FONT BOLD
FACTOR
Set s a scalable font boldfacing am ount , wher e:
08 ( 1 – 36)
I s t he set t ing, based on an increm ent ing scale, w here eight ( 08) is nom inal.
Summary of Contents for I-Class Mark II
Page 1: ...Operator s Manual ...
Page 2: ......
Page 8: ...Chapter 1 Getting Started 2 ...
Page 24: ...Chapter 2 Printer Setup 1 8 ...
Page 64: ...Chapter 4 Menu System 5 8 ...
Page 78: ...Chapter 6 Troubleshooting 7 2 ...
Page 82: ...Appendix A Specifications 7 6 ...
Page 90: ...Appendix B W ireless and W ired LAN Setup 8 4 ...
Page 96: ......