SG4 EXTENDED INSTRUCTION MANUAL
70
8
A critical failure can’t be re-established with a Reset procedure but it’s necessary to switch-
off and switch-on the light curtain; if the failure persists, please contact the Datalogic
Technical Support.
ESPE
WORKING
MODE
INDICATION
LED CONFIGURATION
Off
On
Blink
Indifferent
SUGGESTED ACTION
NORMAL
OPERATION
SHORT RANGE
EMISSION
LONG RANGE
EMISSION
NO CODE
CODE 1
CODE 2
TEST
if undesired Test, check TEST
line connection
EMISSION
FAILURE
FAILURE ON
MICROPROCESSOR
Activate RESET line. If error
persists contact Datalogic
Automation Technical Support
FAILURE ON
OPTICS
Activate RESET line. If error
persists contact Datalogic
Automation Technical Support
BCM
CONFIGURATION
FAILURE
Re-operate Basic Configuration.
If error persists contact Datalogic
Automation Technical Support
COMUNICATION
FAILURE
Check cascade connection and
correct mounting of terminator
cap. Activate RESET line
CRITICAL FAILURE
Turn ON/OFF ESPE. If error
persists contact Datalogic
Automation Technical Support
TX SIDE: