SG4 EXTENDED INSTRUCTION MANUAL
68
8
ESPE
WORKING
MODE
INDICATION
LED CONFIGURATION
Off
On
Blink
Indifferent
SUGGESTED ACTION
NORMAL
OPERATION
BLANKING
ONLY
VALID BLANKING
(OSSDS ON)
INVALID BLANKING
(OSSDS OFF)
blanking zones not
respected
reconfigure blanking (teach-
in if BCM)
BCM TOLERANCE
ACTIVE
check effective ESPE
resolution and intentional
activation of tolerance
function
NORMAL
OPERATION
MUTING ONLY
MUTING ACTIVE
if unexpected OSSD OFF
with muting active, check
partial muting configuration
OVERRIDE ACTIVE
OSSD ON, muting lamp flashing
OVERRIDE
ATTENTION
STATUS
trigger override button to
force OSSDs ON
OVERRIDE TIMINGS
FAILURE
check and repeat override
activation sequence
check override connections
LAMP FAILURE
check if lamp connections
and/or if lamp is broken