SG4 EXTENDED INSTRUCTION MANUAL
18
2
ESPE has to be correctly aligned, press slightly on the product side in both directions
the red LED must not turn on
The activation of the TEST function (on TX side) causes the opening of the OSSD
outputs (red LED, OSSD on RX side, ON and controlled machine stop)
The response time at machine STOP, including the ESPE and machine response
times, must be included in the limits defined in the calculation of the safety distance
(refer to chapter 2)
The safety distance between the dangerous parts and ESPE must comply with the
requirements indicated in chapter 2
A person must not access or remain between ESPE and the dangerous parts of the
machine
Access to the dangerous areas of the machine must not be possible from any
unprotected area
ESPE must not be disturbed by external light sources, ensuring that it remains in
NORMAL OPERATION condition for at least 10-15 minutes and, placing the specific
test piece in the protected area, in the SAFE state for the same period
Verify the correspondence of all the accessory functions, activating them in the
different operating conditions