FUNCTIONS
35
7
BCM Configuration: Restart Mode
Auto
Led 5 ON Red
Manual
Led 5 OFF
ACM Configuration: Restart Mode
7.2 TEST
The TEST function can be activated by pressing the 24VDC normally-open push-button
connected to TX unit TEST input (pin 2 of M12-5 poles) for at least 0.5 seconds.
The TEST disables the emission stage, so the RX side sees interrupted all beams and the
OSSD goes low within response time. As shown in the timing diagram below, the OSSDs go
OFF (BREAK status) after 500msec (plus a cycle time) and after the response time of the
light curtain.
OFF
ON
OFF
ON
TEST
SAFE
NORMAL OPERATION
OSSDs status
EMISSION status
500ms
RESPONSE TIME
RECOVERY TIME
Fig. 34 – Test timings