AMT58x-PN ProfiNET®
65
Velocity measuring units
This parameter defines the coding of the velocity measuring units
used to configure the signals
NIST_A
and
NIST_B
. Standard
telegram 81 has no velocity information included and the encoder
does not use the velocity measuring unit information in this case.
Standard telegrams 82, 83 and 84 include velocity output and need a
declaration of the velocity measuring unit.
Parameter
Meaning
Value
Velocity measuring
units
Definition of the units for the
encoder velocity output value
See table
below
Velocity measuring
units
Value
Steps / s
0
Steps / 100 ms
1
Steps / 10 ms
2
RPM 3
Default = 0 (min. = 0, max. = 3)
NOTE
Please note that the velocity value is always calculated every 100
ms.