91
You have the option of establishing the reserved transmission
bandwidth for IRT data as a proportion of the maximum reservable
transmission bandwidth for cyclic user data communication. The
proportion is specified in percent (%).
In doing so, the maximum transmission bandwidth set by the system
for cyclic data may not be exceeded by the reserved transmission
bandwidth for IRT plus the transmission bandwidth that is required
for the cyclic data in the free transmission bandwidth (RT
communication).
Press the Details... button in the Domain Management dialog box.
The Details – Sync domain dialog box will appear on the screen. In
the Upper limit for IRT drop-down list available in the Cyclic data
group box, select one of the default values (in %). STEP 7 offers the
following selections: 0, 10, ... 100.
Figure 51 - Sync domain details dialog box
The PROFINET IO system of the sync domain is established now on
a send clock.
Save the settings and close both the Details – Sync Domain and the
Domain management dialog boxes pressing the OK button.
Finally save, compile and then download the configuration to the
controller.
Summary of Contents for AMT58*-PN Series
Page 1: ......
Page 16: ......
Page 21: ...AMT58x PN ProfiNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Page 30: ...AMT58x PN ProfiNET 14 Figure 5 Scrolling through Profinet families and categories ...
Page 119: ...AMT58x PN ProfiNET 103 Figure 67 FC1 13 1 9 Function 2 FC2 Figure 68 FC2 ...
Page 123: ...AMT58x PN ProfiNET 107 14 1 Normal operation diagram ...
Page 124: ...AMT58x PN ProfiNET 108 14 2 Preset diagram ...
Page 125: ...AMT58x PN ProfiNET 109 14 3 Parking sensor diagram ...
Page 127: ...AMT58x PN ProfiNET 111 14 4 2 Acknowledgment of not acknowledgeable sensor error ...
Page 145: ......