AMT58x-PN ProfiNET®
90
The Domain Management dialog box will appear on the screen.
Using the Domain management dialog box you can check the
settings of the PROFINET IO system.
The name of the sync domain is automatically assigned by STEP 7
with "syncdomain-default" when the first sync domain is configured.
You find it under the Sync domain item in the Sync domain group
box. Alternatively you can create further sync domains.
The Send clock time (ms) is the period between two successive
intervals for IRT or RT communication. The send clock is the shortest
possible transmit interval for exchanging data. You have the option to
establish the send clock for your sync domain in order to achieve an
optimum coordination of the transmission bandwidth to the data
volume. Depending on the PROFINET devices of the respective
PROFINET IO systems, STEP 7 calculates the possible values that
can be set. Select one of the default send clock time values in the
drop-down list.
Figure 50 - Domain management dialog box