AMT58x-PN ProfiNET®
87
The assigned process image partitions must be updated in the
synchronous cycle interrupt OB61 at the call of the functions SFC126
“SYNC_PI” and SFC127 “SYNC_PO”.
The call of the function SFC126 “SYNC_PI” updates the process
image partition input table; the call of the function SFC127
“SYNC_PO” updates the process image partition output table. So
cyclic interrupt OB61 works with consistent image of the process
signals. Refer also to page 108.
11.5.2 SFC126 “SYNC_PI”
This special function is used to update a process image partition
input table in a synchronous cycle.
Synchronous cycle interrupt OB61 calls the function SFC126
“SYNC_PI” to consistently and synchronously update the input data
located in a process image partition.
11.5.3 SFC127 “SYNC_PO”
This special function update a process image partition output table in
a synchronous cycle.
Synchronous cycle interrupt OB61 calls the function SFC127
“SYNC_PO” to synchronously update the output data located in a
process image partition and consistently transmit them to the
encoder.
Summary of Contents for AMT58*-PN Series
Page 1: ......
Page 16: ......
Page 21: ...AMT58x PN ProfiNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Page 30: ...AMT58x PN ProfiNET 14 Figure 5 Scrolling through Profinet families and categories ...
Page 119: ...AMT58x PN ProfiNET 103 Figure 67 FC1 13 1 9 Function 2 FC2 Figure 68 FC2 ...
Page 123: ...AMT58x PN ProfiNET 107 14 1 Normal operation diagram ...
Page 124: ...AMT58x PN ProfiNET 108 14 2 Preset diagram ...
Page 125: ...AMT58x PN ProfiNET 109 14 3 Parking sensor diagram ...
Page 127: ...AMT58x PN ProfiNET 111 14 4 2 Acknowledgment of not acknowledgeable sensor error ...
Page 145: ......