4.5 Diagnostic LEDs (Fig.1)
Six LEDs located in the cap of the encoder (see Figure 1) are meant
to show visually the operating or fault status of the encoder and the
Profinet interface. The meaning of each LED is explained in the
following tables.
LED
Description
L1 (
green
)
Link 1: link to another Ethernet component through port 1
A1 (
yellow
)
Activity 1: incoming and outgoing traffic through port 1
S1 (
green
)
Status 1: see table below
S2 (
red
)
Status 2: see table below
L2 (
green
)
Link 2: link to another Ethernet component through port 2
A2 (
yellow
)
Activity 2: incoming and outgoing traffic through port 2
S1 Status 1
green
S2 Status 2
red
Meaning
Cause
OFF
OFF No
power
Unit switched off
Cable disconnected
ON
ON
No connection to another
device
Criteria: no data exchange
Bus disconnected
Master not available or
switched off
ON
Blinking
at 1 Hz
Parametrization fault, no
data exchange
Criteria: data exchange is
correct but the encoder
does not switch to the
data exchange mode
Slave not configured yet
or wrong configuration
A wrong address has
been assigned to the unit
Actual configuration of
the slave differs from the
nominal configuration
OFF
ON System
failure
Diagnostic data exists,
slave in data exchange
mode
ON
OFF
Data exchange, the
encoder is working
properly
Correct operation
Blinking
at 1 Hz
OFF
Flash memory upgrade
process is active (see on
page 119)
The user is upgrading the
flash memory
OFF
Blinking
at 1 Hz
Flash memory upgrade
process failed (see on
page 119)
Cable disconnected
Power switched off
Internal error
Flash memory damaged
Upgrade process aborted
before completion
Summary of Contents for AMT58*-PN Series
Page 1: ......
Page 16: ......
Page 21: ...AMT58x PN ProfiNET 5 3 1 3 Installation using a flange code ST 58 FLNG ...
Page 30: ...AMT58x PN ProfiNET 14 Figure 5 Scrolling through Profinet families and categories ...
Page 119: ...AMT58x PN ProfiNET 103 Figure 67 FC1 13 1 9 Function 2 FC2 Figure 68 FC2 ...
Page 123: ...AMT58x PN ProfiNET 107 14 1 Normal operation diagram ...
Page 124: ...AMT58x PN ProfiNET 108 14 2 Preset diagram ...
Page 125: ...AMT58x PN ProfiNET 109 14 3 Parking sensor diagram ...
Page 127: ...AMT58x PN ProfiNET 111 14 4 2 Acknowledgment of not acknowledgeable sensor error ...
Page 145: ......