DM-
SV01 Server ● BMC User Manual ● Rev. 2.1
81
"LowerThresholdNonCritical": 3.1350000000000002,
"MaxReadingRange": 0.0,
"MemberId": "VDD_33_RUN",
"MinReadingRange": 0.0,
"Name": "VDD 33 RUN",
"ReadingVolts": 2.604,
"Status": {
"Health": "OK",
"State": "Enabled"
},
"UpperThresholdCritical": 3.63,
"UpperThresholdNonCritical": 3.465
},
{
"@odata.id": "/redfish/v1/Chassis/chassis/Power#/Voltages/4",
"@odata.type": "#Power.v1_0_0.Voltage",
"LowerThresholdCritical": 4.5,
"LowerThresholdNonCritical": 4.75,
"MaxReadingRange": 0.0,
"MemberId": "VDD_5_DUAL",
"MinReadingRange": 0.0,
"Name": "VDD 5 DUAL",
"ReadingVolts": 5.204,
"Status": {
"Health": "OK",
"State": "Enabled"
},
"UpperThresholdCritical": 5.5,
"UpperThresholdNonCritical": 5.25
}
]
}
Once the operation is successful, it returns the response “200 OK” and the sensors information is
retrieved.