DM-
SV01 Server ● BMC User Manual ● Rev. 2.1
126
"Severity": "Critical"
},
{
"@odata.id": "/redfish/v1/Systems/system/LogServices/EventLog/Entries/82",
"@odata.type": "#LogEntry.v1_4_0.LogEntry",
"Created": "1970-01-01T00:01:22+00:00",
"EntryType": "Event",
"Id": "82",
"Message": "FAN_RIGHT sensor crossed a warning low threshold going low.
Reading=0.000000 Threshold=1500.000000.",
"MessageArgs": [
"FAN_RIGHT",
"0.000000",
"1500.000000"
],
"MessageId": "OpenBMC.0.1.SensorThresholdWarningLowGoingLow",
"Name": "System Event Log Entry",
"Severity": "Warning"
},
{
"@odata.id": "/redfish/v1/Systems/system/LogServices/EventLog/Entries/90",
"@odata.type": "#LogEntry.v1_4_0.LogEntry",
"Created": "1970-01-01T00:01:30+00:00",
"EntryType": "Event",
"Id": "90",
"Message": "FAN_RIGHT sensor crossed a critical low threshold going low.
Reading=0.000000 Threshold=1000.000000.",
"MessageArgs": [
"FAN_RIGHT",
"0.000000",
"1000.000000"
],
"MessageId": "OpenBMC.0.1.SensorThresholdCriticalLowGoingLow",
"Name": "System Event Log Entry",
"Severity": "Critical"
}
],
"[email protected]": 4,
"Name": "System Event Log Entries"
}
Once the operation is successful, it returns the response “200 OK” and the logs are shown in the body
of the request response.