![DATACOM TEXTRON LANcat OneWay User Manual Download Page 46](http://html.mh-extra.com/html/datacom-textron/lancat-oneway/lancat-oneway_user-manual_511581046.webp)
LANcat
User Manual
Page 4-4
Viewing Quick Check Results
Viewing the results of Quick Check is the same as for Autotest,
except that they cannot be saved. Refer to Viewing Autotest
Results in Chapter 3, Autotest.
Marginal Test Results
A PASS* or FAIL* result indicates that a measured NEXT
or attenuation value is close enough to the Test Standard that
it is within the measurement uncertainty of the LANcat. As a
result, the PASS or FAIL judgment is uncertain, and
therefore the LANcat can not determine with confidence that
the link conforms to the Test Standard.
The following steps may be taken in order to resolve link
tests with marginal measured results:
1.
Reduce the measurement uncertainty. If you are currently
using a Level I-rated Performance Module (PM), replace it
with a Level II-rated PM and retest. If the test result is still
marginal, or if you are already using a Level II-rated PM,
proceed to the next step.
2.
Recheck the link installation, focusing on connection
points. Refer to Chapter 7, Testing Twisted Pairs, for
suggestions on causes for excessive NEXT and
attenuation. Correct installation if possible, and retest.