LANcat
User Manual
Page 7-14
The following troubleshooting table describes some common
NEXT problems and some solutions.
Test Results
Possible Solutions
NEXT test fails
for one or more
pairs
Compare test results to actual expected values
to confirm misconformance.
Start at tester end and check that all cable is
minimum required grade.
Check termination hardware to make sure all
hardware is at least the minimum grade
expected. For example, if testing for Category
3, you could use Category 3, 4 or 5
components. If testing to Category 5, you can
only use Category 5 components.
Check that termination points meet
installation standards. Reference the
specification you are using. Re-terminate all
connections as necessary.
Run Wire Map to check for split pairs. Follow
procedure for “Split Pair” in Wire Map
section.
NEXT test fails
in one direction
but not in the
other
Check the terminations closest to where the
faulty readings were detected. Follow
procedure for “NEXT test fails for one or
more pairs” to locate fault.
NEXT test
indicates a split
pair
Follow procedure for “Split pair” in WIRE
MAP section.