Programming Flowcharts
79
4
4
4
4
4
4
4
4
4
Single-Value Operations
Set the subsystem parameters
).
Set the data flow to OL_DF_SINGLEVALUE
using
olDaSetDataFlow
.
Get a handle to the subsystem with
olDaGetDASS
.
1
Initialize the device driver and get the
device handle with
olDaInitialize
.
Configure the subsystem using
olDaConfig
.
Go to the next page.
Specify A/D for an analog input subsystem or for
digital channel 16 (which corresponds to the
digital input port), D/A for an analog output
subsystem, DIN for a digital input subsystem, or
DOUT for a digital output subsystem.
Note that you cannot perform a single-value
analog output operation while the A/D subsystem
is running.
1
For the DIN subsystem, element 0 corresponds to Port A (lines 0 to 7), for
the DOUT subsystem, element 0 corresponds to Port B (lines 0 to 7).