A/D FIFO Full Flag set to 1
−
The data was not read fast enough
by the host computer. The host computer can clear this error.
To avoid this error, ensure that you allocated at least three
buffers, each at least as large as the sampling rate; for example, if
you are using a sampling rate of 100 kSamples/s (100 kHz),
specify a buffer size of 100,000 samples for each buffer.
If one of these error conditions occurs, the module reports the
error but continues to acquire and transfer data to the host
computer.
Note:
The LED on the front panel will not blink green if the
hardware detects an error.