Chapter 2
52
The duty cycle (or pulse width) indicates the percentage of the total
pulse output period that is active. A duty cycle of 50, then, indicates
that half of the total pulse is low and half of the total pulse output is
high. You specify the duty cycle in software.
Note:
The minimum pulse width must be 650 ns.
illustrates a low-to-high pulse with a duty cycle of
approximately 30%.
Figure 6: Example of a Low-to-High Pulse Output Type
Total Pulse Period
Active Pulse
low pulse
high pulse