8.5 PROFINET-specific Parameter List
Parameter
Default value
Range
Conver-
sion index
Data type
8-01 Control Site
[0] Dig. & ctrl. word
[0-2]
-
Uint8
Parameter 8-02 Control Source
[0] FC RS485
[0-4]
-
Uint8
Parameter 8-03 Control Timeout Time
1
0.1-18000
-1
Uint32
Parameter 8-04 Control Timeout
Function
[0] Off
[0-10]
-
Uint8
8-05 End-of-Timeout Function
[0] Hold set-up
[0-1]
-
Uint8
Parameter 8-06 Reset Control Timeout
[0] Do not reset
[0-1]
-
Uint8
Parameter 8-07 Diagnosis Trigger
[0] Disable
[0-3]
-
Uint8
Parameter 8-10 Control Profile
[0] FC profile
[0-x]
-
Uint8
8-13 Configurable Status Word STW
8-50 Coasting Select
[3] *Logic OR
[0-3]
-
Uint8
Parameter 8-51 Quick Stop Select
[3] *Logic OR
[0-3]
-
Uint8
8-52 DC Brake Select
[3] *Logic OR
[0-3]
-
Uint8
8-53 Start Select
[3] *Logic OR
[0-3]
-
Uint8
Parameter 8-54 Reversing Select
[3] *Logic OR
[0-3]
-
Uint8
8-55 Set-up Select
[3] *Logic OR
[0-3]
-
Uint8
8-56 Preset Reference Select
[3] *Logic OR
[0-3]
-
Uint8
8-90 Bus Jog 1 Speed
100 rpm
0-
4-13 Motor Speed High
Limit [RPM]
67
Uint16
8-91 Bus Jog 2 Speed
200 rpm
0-
4-13 Motor Speed High
Limit [RPM]
67
Uint16
9-15 PCD Write Configuration
-
-
-
Uint16
9-16 PCD Read Configuration
-
-
-
Uint16
Parameter 9-22 Telegram Selection
-
[0-108]
-
Uint8
Parameter 9-23 Parameters for Signals
-
0-573
-
Uint16
Parameter 9-27 Parameter Edit
[1] Enabled
[0-1]
-
Uint16
9-28 Process Control
[1] Enable cyclic master
[0-1]
-
Uint16
9-44 Fault Message Counter
0
[0-8]
0
Uint16
9-45 Fault Code
0
-
-
Uint16
9-47 Fault Number
0
-
-
Uint16
9-52 Fault Situation Counter
0
0-1000
0
Uint16
9-53 Profibus Warning Word
0
16 bits
0
V2
9-64 Device Identification
0
[0-10]
0
Uint16
9-65 Profile Number
0
8 bits
0
Uint8
Parameter 9-70 Programming Set-up
[9] Active set-up
[0-9]
-
Uint8
Parameter 9-71 Profibus Save Data
Values
[0] Off
[0-2]
-
Uint8
9-72 ProfibusDriveReset
[0] No action
[0-2]
-
Uint8
9-80 Defined Parameters (1)
-
0-115
0
Uint16
9-81 Defined Parameters (2)
0-115
0
Uint16
9-82 Defined Parameters (3)
-
0-115
0
Uint16
9-83 Defined Parameters (4)
-
0-115
0
Uint16
9-90 Changed Parameters (1)
-
0-115
0
Uint16
9-91 Changed Parameters (2)
-
0-115
0
Uint16
9-92 Changed Parameters (3)
-
0-115
0
Uint16
9-93 Changed Parameters (4)
-
0-115
0
Uint16
12-00 IP Address Assignment
0.0.0.0
0-255
-
Unsigned 8
12-01 IP Address
0.0.0.0
0-255
-
Oct. string 4
Parameter 12-02 Subnet Mask
0.0.0.0
0-255
-
Oct. string 4
12-03 Default Gateway
0.0.0.0
0-255
-
Oct. string 4-
Parameters
Operating Instructions
54
Danfoss A/S © Rev. 2014-02-27 All rights reserved.
MG90U302
8
8
Summary of Contents for VLT PROFINET MCA 120
Page 2: ......