8.4 Parameter Group 12-** Ethernet
8.4.1 12-0* IP Settings
12-00 IP Address Assignment
Option:
Function:
Selects the IP Address assignment method.
[0]
MANUAL
IP-address can be set in
parameter 12-01 IP
Address
IP Address.
[1]
DHCP
IP-address is assigned via DHCP server.
[2]
BOOTP
IP-address is assigned via BOOTP server.
[10] DCP
DCP Assigned via the DCP protocol.
[20] From node ID
12-01 IP Address
Range:
Function:
0
*
[0 -
2147483647 ]
Configure the IP address of the option.
Read-only if
parameter 12-00 IP Address
Assignment
set to DHCP or BOOTP. In
POWERLINK the IP address follows the
12-60 Node ID
last byte and the first part is
fixed to 192.168.100 (Node ID).
12-02 Subnet Mask
Range:
Function:
0
*
[0 -
4244635647 ]
Configure the IP subnet mask of the
option. Read-only if
parameter 12-00 IP
Address Assignment
set to DHCP or BOOTP.
In POWERLINK it is fixed to 255.255.255.0.
12-03 Default Gateway
Range:
Function:
0
*
[0 -
2147483647 ]
Configure the IP default gateway of the
option. Read-only if
parameter 12-00 IP
Address Assignment
set to DHCP or BOOTP.
In a non-routed network this address is set
to the IP address of the IO Device
12-04 DHCP Server
Range:
Function:
0
*
[0 - 2147483647 ] Read only. Displays the IP address of the
found DHCP or BOOTP server.
12-05 Lease Expires
Range:
Function:
Size related
*
[ 0 - 0 ] Read only. Displays the lease-time left for
the current DHCP-assigned IP address.
12-06 Name Servers
Range:
Function:
0
*
[0 - 2147483647 ] IP addresses of Domain Name Servers.
Can be automatically assigned when
using DHCP.
12-07 Domain Name
Range:
Function:
0
[0 - 48 ] Domain name of the attached network. Can be
automatically assigned when using DHCP network.
12-08 Host Name
Range:
Function:
0
*
[0 - 48 ]
Logical (given) name of option.
NOTICE
The display of the frequency converter only shows the
first 19 characters, but the remaining characters are
stored in the frequency converter. If Hardware switches
are different from all ON or all OFF, the switches has
priority.
12-09 Physical Address
Range:
Function:
0
*
[0 - 17 ] Read only. Displays the Physical (MAC) address of
the option.
8.4.2 12-1* Ethernet Link Parameters
Applies for whole parameter group.
Index [0] is used for Port 1 and Index [1] is used for Port 2.
For EtherCAT, Index [0] is for In Port and Index [1] is for
Out port.
12-10 Link Status
Option:
Function:
Read only. Displays the link status of the Ethernet
ports.
[0]
*
No Link
[1]
Link
12-11 Link Duration
Range:
Function:
Size related
*
[ 0 - 0 ] Read only. Displays the duration of the
present link on each port in dd:hh:mm:ss.
12-12 Auto Negotiation
Option: Function:
Configures Auto Negotiation of Ethernet link
parameters, for each port: ON or OFF.
[0]
Off
Link Speed
and
Link Duplex
can be configured in
parameter 12-13 Link Speed
and
12-14 Link Duplex
.
[1]
*
On
NOTICE
In POWERLINK this parameter is fixed to OFF setting.
Parameters
Operating Instructions
MG90U302
Danfoss A/S © Rev. 2014-02-27 All rights reserved.
51
8
8
Summary of Contents for VLT PROFINET MCA 120