Pa
r.
No
.
#
Pa
ramete
r description
Def
ault value
4 s
et
-u
p
Change during
ope
rat
ion
Con
ver-
sio
n index
Typ
e
15
-0* Ope
rat
in
g D
ata
15-
00
Op
er
ati
ng
Ho
urs
0 h
Al
l set-ups
FAL
SE
74
Uint32
15-
01
Run
ning
H
our
s
0 h
Al
l set-ups
FA
LS
E
74
Ui
nt3
2
15-
02
kWh
Counter
0 kWh
Al
l set-
ups
FAL
SE
75
Uint32
15-
03
Pow
er-
ups
0 N/A
Al
l set-ups
FA
LS
E
0
Ui
nt3
2
15-
04
Ove
rtemp
s
0 N/A
Al
l set-
ups
FAL
SE
0
U
int16
15-
05
Ove
rvol
ts
0 N/A
Al
l set-ups
FA
LS
E
0
Ui
nt1
6
15-
06
R
ese
t kWh
Co
un
te
r
[0]
Do
n
ot reset
All set-
ups
TRUE
-
Uint8
15-
07
Re
set Running Hours C
ounte
r
[0]
Do
n
ot re
se
t
Al
l set-ups
TRU
E
-
Ui
nt8
15-
08
Numb
er of
S
tart
s
0 N/A
Al
l set-ups
FA
LS
E
0
Ui
nt3
2
15
-1* Dat
a Log
S
ett
in
gs
15-
10
Lo
gg
in
g So
urce
0
2 set-
ups
TRUE
-
Uint16
15-
11
Lo
gg
in
g I
nterv
al
Ex
pressionLimit
2 s
et
-u
ps
TRU
E
-3
TimD
15-
12
Tri
gg
er Eve
nt
[0] Fal
se
1
se
t-up
TR
UE
-
U
int8
15-
13
Lo
gg
in
g M
od
e
[0] Log
al
ways
2 s
et
-u
ps
TRU
E
-
Ui
nt8
15-
14
Sa
mp
les B
efor
e Tr
igg
er
50 N/
A
2 s
et
-u
ps
TRU
E
0
Ui
nt8
15
-2* Hist
ori
c Log
15-
20
H
isto
ric
L
og:
Eve
nt
0 N/A
Al
l set-ups
FAL
SE
0
U
int8
15-
21
Hi
stori
c Log: V
alue
0 N/A
Al
l set-ups
FA
LS
E
0
Ui
nt3
2
15-
22
Hi
stori
c Lo
g: Tim
e
0 ms
Al
l set-ups
FAL
SE
-3
Uint32
15-
23
H
isto
ric
L
og:
Date
a
nd
Ti
me
Ex
pressionLimit
Al
l set-ups
FA
LS
E
0
Tim
eOf
Day
15
-3* Al
arm Log
15-
30
Al
ar
m
Log: Erro
r C
ode
0 N/A
Al
l set-ups
FA
LS
E
0
Ui
nt8
15-
31
Al
arm L
og
:
Va
lu
e
0 N/A
Al
l set-
ups
FAL
SE
0
Int16
15-
32
Al
ar
m L
og:
Ti
me
0 s
Al
l set-ups
FA
LS
E
0
Ui
nt3
2
15-
33
Al
arm Lo
g:
D
ate
a
nd
Ti
me
Ex
pressionLimit
Al
l set-ups
FA
LS
E
0
Tim
eOf
Day
15
-4* Dr
iv
e I
d
en
ti
fi
cat
ion
15-
40
FC Typ
e
0 N/A
Al
l set-ups
FAL
SE
0
Vi
sSt
r[6
]
15-
41
Pow
er Secti
on
0 N/A
Al
l set-ups
FA
LS
E
0
Vi
sStr[20]
15-
42
Vo
ltag
e
0 N/A
Al
l se
t-up
s
FAL
SE
0
VisStr[20]
15-
43
Sof
twa
re Ve
rsi
on
0 N/A
Al
l set-ups
FA
LS
E
0
Vi
sSt
r[5
]
15-
44
Ord
ered
Typ
eco
de
S
tri
ng
0 N/A
Al
l se
t-up
s
FAL
SE
0
VisStr[40]
15-
45
Actual
T
ype
co
de
String
0 N/A
Al
l set-ups
FA
LS
E
0
Vi
sStr[40]
15-46
Adjust
able Fre
que
ncy Drive
Ordering
No.
0
N/A
Al
l set-up
s
FAL
SE
0
Vi
sSt
r[8
]
15-
47
Power Card Orde
ring
No
.
0 N/A
Al
l set-ups
FA
LS
E
0
Vi
sSt
r[8
]
15-
48
LCP
I
D
No
0 N/A
Al
l se
t-up
s
FAL
SE
0
VisStr[20]
15-
49
SW ID C
ontro
l Card
0 N/A
Al
l set-ups
FA
LS
E
0
Vi
sStr[20]
15-
50
SW I
D
P
owe
r Card
0
N/A
Al
l se
t-up
s
FAL
SE
0
VisStr[20]
15-
51
Adjust
able Fre
que
ncy Drive
Se
ria
l Numbe
r
0 N/A
Al
l set-ups
FA
LS
E
0
Vi
sStr[10]
15-
53
Po
we
r Card
Seri
al
Numb
er
0
N/A
Al
l se
t-up
s
FAL
SE
0
VisStr[19]
6.2.14.
15-** FC Information
6. How to program the adjustable frequency
drive
VLT
®
HVAC Drive Instruction Manual
116
MG.11.A4.22 - VLT
®
is a registered Danfoss trademark
6