5.1.22 24-** Application Functions 2
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
24-0* Fire Mode
24-00 Fire Mode Function
[0] Disabled
2 set-ups
TRUE
-
Uint8
24-01 Fire Mode Configuration
[0] Open Loop
All set-ups
TRUE
-
Uint8
24-02 Fire Mode Unit
ExpressionLimit
All set-ups
TRUE
-
Uint8
24-03 Fire Mode Min Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
24-04 Fire Mode Max Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
24-05 Fire Mode Preset Reference
0 %
All set-ups
TRUE
-2
Int16
24-06 Fire Mode Reference Source
[0] No function
All set-ups
TRUE
-
Uint8
24-07 Fire Mode Feedback Source
[0] No function
All set-ups
TRUE
-
Uint8
24-09 Fire Mode Alarm Handling
[1] Trip, Critical
Alarms
2 set-ups
FALSE
-
Uint8
24-1* Drive Bypass
24-10 Drive Bypass Function
[0] Disabled
2 set-ups
TRUE
-
Uint8
24-11 Drive Bypass Delay Time
0 s
2 set-ups
TRUE
0
Uint16
24-9* Multi-Motor Funct.
24-90 Missing Motor Function
[0] Off
All set-ups
TRUE
-
Uint8
24-91 Missing Motor Coefficient 1
0 N/A
All set-ups
TRUE
-4
Int32
24-92 Missing Motor Coefficient 2
0 N/A
All set-ups
TRUE
-4
Int32
24-93 Missing Motor Coefficient 3
0 N/A
All set-ups
TRUE
-4
Int32
24-94 Missing Motor Coefficient 4
0 N/A
All set-ups
TRUE
-3
Int32
24-95 Locked Rotor Function
[0] Off
All set-ups
TRUE
-
Uint8
24-96 Locked Rotor Coefficient 1
0 N/A
All set-ups
TRUE
-4
Int32
24-97 Locked Rotor Coefficient 2
0 N/A
All set-ups
TRUE
-4
Int32
24-98 Locked Rotor Coefficient 3
0 N/A
All set-ups
TRUE
-4
Int32
24-99 Locked Rotor Coefficient 4
0 N/A
All set-ups
TRUE
-3
Int32
5.1.23 25-** Cascade Pack Controller
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
25-0* System Settings
25-00 Cascade Controller
[0] Disabled
2 set-ups
FALSE
-
Uint8
25-02 Motor Start
[0] Direct on Line
2 set-ups
FALSE
-
Uint8
25-04 Pump Cycling
[0] Disabled
All set-ups
TRUE
-
Uint8
25-05 Fixed Lead Pump
[1] Yes
2 set-ups
FALSE
-
Uint8
25-06 Number of Pumps
2 N/A
2 set-ups
FALSE
0
Uint8
25-2* Bandwidth Settings
25-20 Staging Bandwidth
10 %
All set-ups
TRUE
0
Uint8
25-21 Override Bandwidth
100 %
All set-ups
TRUE
0
Uint8
25-22 Fixed Speed Bandwidth
casco_staging_band
width (P2520)
All set-ups
TRUE
0
Uint8
25-23 SBW Staging Delay
15 s
All set-ups
TRUE
0
Uint16
25-24 SBW Destaging Delay
15 s
All set-ups
TRUE
0
Uint16
25-25 OBW Time
10 s
All set-ups
TRUE
0
Uint16
25-26 Destage At No-Flow
[0] Disabled
All set-ups
TRUE
-
Uint8
25-27 Stage Function
[1] Enabled
All set-ups
TRUE
-
Uint8
25-28 Stage Function Time
15 s
All set-ups
TRUE
0
Uint16
25-29 Destage Function
[1] Enabled
All set-ups
TRUE
-
Uint8
25-30 Destage Function Time
15 s
All set-ups
TRUE
0
Uint16
25-4* Staging Settings
Parameter Lists
VLT
®
HVAC Drive FC 102
242