FC 302
Vertical braking 40% duty cycle
Frequency converter data
Brake resistor data
Installation
R
rec
[
Ω
]
P
br.cont.
[kW]
Danfoss part number
Cable
cross
section
[mm
2
]
Thermo
relay
[A]
Mains
type
P
m
[kW]
R
min
[
Ω
]
R
br.nom
[
Ω
]
Wire IP54
Screw
terminal
IP21
Screw
terminal
IP65
Bolt
connection
IP20
T5
0.37
1000
1389.2
1200
0.200
175u3101
-
-
-
1.5
0.4
T5
0.55
620
928.8
850
0.200
175u3308
-
-
-
1.5
0.5
T5
0.75
558
678.3
630
0.300
175u3309
-
-
-
1.5
0.7
T5
1.1
382
452.5
410
0.450
175u3310 175u3416 175u3415
-
1.5
1
T5
1.5
260
325.9
270
0.570
175u3311 175u3418 175u3417
-
1.5
1.4
T5
2.2
189
218.6
200
0.960
175u3312 175u3420 175u3419
-
1.5
2.1
T5
3
135
158.5
145
1.130
175u3313 175u3422 175u3421
-
1.5
2.7
T5
4
99.0
117.2
110
1.700
175u3314 175u3424 175u3423
-
1.5
3.7
T5
5.5
72.0
84.4
80
2.200
175u3315 175u3138 175u3139
-
1.5
5
T5
7.5
50.0
61.4
56
3.200
175u3316 175u3428 175u3427
-
1.5
7.1
T5
11
36.0
41.2
38
5.000
-
-
-
175u3236
1.5
11.5
T5
15
27.0
30.0
28
6.000
-
-
-
175u3237
2.5
14.7
T5
18.5
20.3
24.2
22
8.000
-
-
-
175u3238
4
19
T5
22
18.0
20.3
19
10.000
-
-
-
175u3203
4
23
T5
30
13.4
15.8
14
14.000
-
-
-
175u3206
10
32
T5
37
10.8
12.7
12
17.000
-
-
-
175u3210
10
38
T5
45
8.8
10.4
9.5
21.000
-
-
-
175u3213
16
47
T5
55
6.5
8.5
7.0
26.000
-
-
-
175u3216
25
61
T5
75
4.2
6.2
5.5
36.000
-
-
-
175u3219
35
81
Table 7.13 T5, Vertical Braking 40% Duty Cycle
How to Order
VLT
®
AutomationDrive FC 301/FC 302 Design Guide, 0.25-75 kW
MG33BF02 - Rev. 2013-12-20
95
7
7