![background image](http://html1.mh-extra.com/html/danfoss/vlt-5000-series/vlt-5000-series_design-manual_3452348038.webp)
Electrical data
Bookstyle and Compact, Mains supply 3 x 200 - 240 V
According to international requirements
VLT type
5001
5002
5003
5004
5005
5006
Output current
I
VLT,N
[A]
3.7
5.4
7.8
10.6
12.5
15.2
I
VLT, MAX
(60 s) [A]
5.9
8.6
12.5
17
20
24.3
Output (240 V)
S
VLT,N
[kVA]
1.5
2.2
3.2
4.4
5.2
6.3
Typical shaft output
P
VLT,N
[kW]
0.75
1.1
1.5
2.2
3.0
3.7
Typical shaft output
P
VLT,N
[HP]
1
1.5
2
3
4
5
Max. cable cross-section to motor,
brake and loadsharing [mm
2
]/[AWG]
2
)
4/10
4/10
4/10
4/10
4/10
4/10
Rated input current
(200 V)I
L,N
[A]
3.4
4.8
7.1
9.5
11.5
14.5
Max. cable
cross-section power [mm
2
]/[AWG]
2
)
4/10
4/10
4/10
4/10
4/10
4/10
Max. pre-fuses
[-]/UL
1)
[A]
16/10
16/10
16/15
25/20
25/25
35/30
Efficiency
3)
0.95
0.95
0.95
0.95
0.95
0.95
Weight IP 20 EB Bookstyle
[kg]
7
7
7
9
9
9.5
Weight IP 20 EB Compact [kg]
8
8
8
10
10
10
Weight IP 54 Compact
[kg]
11.5
11.5
11.5
13.5
13.5
13.5
Power loss at
max. load.
[W]
58
76
95
126
172
194
Enclosure
IP 20/
IP54
IP 20/
IP54
IP 20/
IP54
IP 20/
IP54
IP 20/
IP54
IP 20/
IP54
1. For type of fuse see section
Fuses.
2. American Wire Gauge.
3. Measured using 30 m screened motor cables at rated load and rated frequency.
VLT
®
5000 Design Guide
MG.52.B2.02 - VLT
®
is a registered Danfoss trademark
37
Technical dat
a