Compact, Mains supply 3 x 380 - 500 V
According to international requirements
VLT type 5122
5152
5202
5252
5302
Normal overload current (110 %):
Output current
I
VLT,N
[A] (380-415 V)
212
260
315
395
480
I
VLT, MAX
(60 s) [A] (380-415
V)
233
286
347
434
528
I
VLT,N
[A] (440-500 V)
190
240
302
361
443
I
VLT, MAX
(60 s) [A] (440-500
V)
209
264
332
397
487
Output
S
VLT,N
[kVA] (400 V)
147
180
218
274
333
S
VLT,N
[kVA] (460 V)
151
191
241
288
353
S
VLT,N
[kVA] (500 V)
165
208
262
313
384
Typical shaft output
[kW] (400 V)
110
132
160
200
250
[HP] (460 V)
150
200
250
300
350
[kW] (500 V)
132
160
200
250
315
High overload torque (160 %):
Output current
I
VLT,N
[A] (380-415 V)
177
212
260
315
395
I
VLT, MAX
(60 s) [A] (380-415
V)
266
318
390
473
593
I
VLT,N
[A] (441-500 V)
160
190
240
302
361
I
VLT, MAX
(60 s) [A] (440-500
V)
240
285
360
453
542
Output
S
VLT,N
[kVA] (400 V)
123
147
180
218
274
S
VLT,N
[kVA] (460 V)
127
151
191
241
288
S
VLT,N
[kVA] (500 V)
139
165
208
262
313
Typical shaft output
[kW] (400 V)
90
110
132
160
200
[HP] (460 V)
125
150
200
250
300
[kW] (500 V)
110
132
160
200
250
Max. cable cross-section to
motor
[mm
2
]
4,6
[AWG]
2,4,6
2 x 70
2 x 2/0
2 x 185
2 x 350 mcm
Max. cable cross-section to
loadsharing and brake
[mm
2
]
4,6
[AWG]
2,4,6
2 x 70
2 x 2/0
2 x 185
2 x 350 mcm
Normal overload current (110 %):
Rated input current
I
L,N
[A] (380-415 V)
208
256
317
385
467
I
L,N
[A] (440-500 V)
185
236
304
356
431
High overload torque (160 %):
Rated input current
I
L,N
[A] (380-415 V)
174
206
256
318
389
I
L,N
[A] (440-500 V)
158
185
236
304
356
Max. cable cross-section
power supply
[mm
2
]
4,6
[AWG]
2,4,6
2 x 70
2 x 2/0
2 x 185
2 x 350 mcm
Max. pre-fuses (mains) [-]/
UL
[A]
1
300/
300
350/
350
450/
400
500/
500
630/
600
Efficiency
3
0,98
Power loss
Normal overload [W]
2619
3309
4163
4977
6107
High overload [W]
2206
2619
3309
4163
4977
Weight
IP 00 [kg]
82
91
112
123
138
Weight
IP 21/Nema1 [kg]
96
104
125
136
151
Weight
IP 54/Nema12 [kg]
96
104
125
136
151
Enclosure
IP 00, IP 21/Nema 1 and IP 54/Nema12
1. For type of fuse see section
Fuses
2. American Wire Gauge.
3. Measured using 30 m screened motor cables at rated load and rated frequency.
4. Max. cable cross-section is the maximum possible cable cross-section allowed to be fitted on the terminals. Always comply with
national and local regulations on min. cable cross-section.
5. Weight without shipping container.
6. Connection bolt power supply and motor: M10; Brake and loadsharing: M8
VLT
®
5000 Design Guide
MG.52.B2.02 - VLT
®
is a registered Danfoss trademark
45