5.5.3 DSP 402 State Transitions
Transition State
Control word Status word Action
-
Start condition
0000
0000
-
0
Start-up
⇒
Not ready to switch on
0000
0200
-
1
Switch On Disabled
⇒
Switch On Disabled
0000, 0001
0240
-
2
Not Ready to Switch On
⇒
Switched On
0006
0231
-
3
Ready to Switch On
⇒
Switched On
0007
0233
-
4
Switched On
⇒
Ready to Switch On
000F
0237
-
5
Operation Enabled
⇒
Switched On
0007
0233
Motor ramps to 0 RPM with programmed ramp
down parameter.
6
Switched On
⇒
Ready to Switch On
0006
0231
-
7
Ready to Switch On
⇒
Switch On Disable
0001, 0000
0240
-
8
Operation Enable
⇒
Ready to Switch On
0006
0231
If the motor is not braked, and the power section is
switched off immediately, the motor is free to
rotate.
9
Operation Enable
⇒
Switch On Disable
0001, 0000
0240
If the motor is not braked, and the power section is
switched off immediately, the motor is free to
rotate.
10
Switched On
⇒
Switched On Disable
0001, 0000
0240
If the motor is not braked, and the power section is
switched off immediately, the motor is free to
rotate.
11
Operation Enabled
⇒
Quick Stop Active
0002
0207
Motor ramps to 0 RPM with programmed quick
ramp parameter.
11
Operation Enabled
⇒
Quick Stop Active
0003
0217
Motor ramps to 0 RPM with programmed quick
ramp parameter.
12
Quick Stop Active
⇒
Switch On Disabled
0001, 0000
0240
If the motor is not braked, and the power section is
switched off immediately, the motor is free to
rotate.
13
All states
⇒
Fault Reaction Active
xxxx
023F
-
14
Fault Reaction Active
⇒
Fault
xxxx
023F
-
15
Fault
⇒
Switch On Disabled
0000
0240
-
16
Quick Stop Active
⇒
Operation Enable (not
supported)
-
-
-
Table 5.12 DSP 402 State Transitions
How to Control the Frequenc...
MCA 123 POWERLINK Operating Instructions
22