23. Lubricate the O-rings, side plate and
flange with clean filtered water.
Mount the first O-ring (pos. 139)
in the cut out in the flange.
24. Mount the second new O-ring
(pos. 137) in the bottom on the flange.
25. It is important that the inside groove in
the side plates are pointing upwards.
26. The outer surface of the side plate
should be flush with the flange when
pushed down. Ones the push is
removed the side plate will move
out a little due to the o-ring below
29. Install the two pins in the vane pump
housing. Spray with clean filtered water
before installint the portflange.
27. Install the housing O-ring and lubricate
it with clean filtered water.